Cargando…

Simulation of Energy Response Linearity, Resolution and $e^-/\pi$ Ratio for the CASTOR Calorimeter at CMS

The response linearity, the energy resolution and the e^-/\pi ratio for the CMS CASTOR calorimeter is studied using gammas, electrons and pions in the energy range of 20 - 1000 GeV CASTOR is going to be installed at the very forward region of the CMS experiment.

Detalles Bibliográficos
Autores principales: Katsas, Panagiotis, Panagiotou, Apostolos
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:http://cds.cern.ch/record/1000389
_version_ 1780911565292175360
author Katsas, Panagiotis
Panagiotou, Apostolos
author_facet Katsas, Panagiotis
Panagiotou, Apostolos
author_sort Katsas, Panagiotis
collection CERN
description The response linearity, the energy resolution and the e^-/\pi ratio for the CMS CASTOR calorimeter is studied using gammas, electrons and pions in the energy range of 20 - 1000 GeV CASTOR is going to be installed at the very forward region of the CMS experiment.
id cern-1000389
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-10003892019-09-30T06:29:59Zhttp://cds.cern.ch/record/1000389engKatsas, PanagiotisPanagiotou, ApostolosSimulation of Energy Response Linearity, Resolution and $e^-/\pi$ Ratio for the CASTOR Calorimeter at CMSDetectors and Experimental TechniquesThe response linearity, the energy resolution and the e^-/\pi ratio for the CMS CASTOR calorimeter is studied using gammas, electrons and pions in the energy range of 20 - 1000 GeV CASTOR is going to be installed at the very forward region of the CMS experiment.CMS-NOTE-2006-147oai:cds.cern.ch:10003892006-04-12
spellingShingle Detectors and Experimental Techniques
Katsas, Panagiotis
Panagiotou, Apostolos
Simulation of Energy Response Linearity, Resolution and $e^-/\pi$ Ratio for the CASTOR Calorimeter at CMS
title Simulation of Energy Response Linearity, Resolution and $e^-/\pi$ Ratio for the CASTOR Calorimeter at CMS
title_full Simulation of Energy Response Linearity, Resolution and $e^-/\pi$ Ratio for the CASTOR Calorimeter at CMS
title_fullStr Simulation of Energy Response Linearity, Resolution and $e^-/\pi$ Ratio for the CASTOR Calorimeter at CMS
title_full_unstemmed Simulation of Energy Response Linearity, Resolution and $e^-/\pi$ Ratio for the CASTOR Calorimeter at CMS
title_short Simulation of Energy Response Linearity, Resolution and $e^-/\pi$ Ratio for the CASTOR Calorimeter at CMS
title_sort simulation of energy response linearity, resolution and $e^-/\pi$ ratio for the castor calorimeter at cms
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1000389
work_keys_str_mv AT katsaspanagiotis simulationofenergyresponselinearityresolutionandepiratioforthecastorcalorimeteratcms
AT panagiotouapostolos simulationofenergyresponselinearityresolutionandepiratioforthecastorcalorimeteratcms