Cargando…
A PET imaging system dedicated to mammography
The imaging system Clear-PEM for positron emission mammography, under development within the framework of the Crystal Clear Collaboration at CERN, is presented. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes (APD) and readout by a fast low-noise electroni...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.radphyschem.2006.03.065 http://cds.cern.ch/record/1006132 |
_version_ | 1780911765185363968 |
---|---|
author | Varela, J |
author_facet | Varela, J |
author_sort | Varela, J |
collection | CERN |
description | The imaging system Clear-PEM for positron emission mammography, under development within the framework of the Crystal Clear Collaboration at CERN, is presented. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes (APD) and readout by a fast low-noise electronic system. A dedicated digital trigger and data acquisition system is used for on-line selection of coincidence events with high efficiency, large bandwidth and negligible dead-time. The detector module performance was characterized in detail. |
id | cern-1006132 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10061322019-09-30T06:29:59Zdoi:10.1016/j.radphyschem.2006.03.065http://cds.cern.ch/record/1006132engVarela, JA PET imaging system dedicated to mammographyHealth Physics and Radiation EffectsThe imaging system Clear-PEM for positron emission mammography, under development within the framework of the Crystal Clear Collaboration at CERN, is presented. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes (APD) and readout by a fast low-noise electronic system. A dedicated digital trigger and data acquisition system is used for on-line selection of coincidence events with high efficiency, large bandwidth and negligible dead-time. The detector module performance was characterized in detail.oai:cds.cern.ch:10061322007 |
spellingShingle | Health Physics and Radiation Effects Varela, J A PET imaging system dedicated to mammography |
title | A PET imaging system dedicated to mammography |
title_full | A PET imaging system dedicated to mammography |
title_fullStr | A PET imaging system dedicated to mammography |
title_full_unstemmed | A PET imaging system dedicated to mammography |
title_short | A PET imaging system dedicated to mammography |
title_sort | pet imaging system dedicated to mammography |
topic | Health Physics and Radiation Effects |
url | https://dx.doi.org/10.1016/j.radphyschem.2006.03.065 http://cds.cern.ch/record/1006132 |
work_keys_str_mv | AT varelaj apetimagingsystemdedicatedtomammography AT varelaj petimagingsystemdedicatedtomammography |