Cargando…

Saturation and Energy Corrections for TeV Electrons and Photons

This note presents a study of the response of the CMS electromagnetic calorimeter ECAL to high energy electrons and photons (from 500 to 4000 GeV), using the full simulation of the CMS detector. The longitudinal containment and the lateral extension of high energy showers are discussed, and energy a...

Descripción completa

Detalles Bibliográficos
Autores principales: Clerbaux, Barbara, Elgammal, Sherif, Mahmoud, Tariq, Marage, Pierre Edouard
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:http://cds.cern.ch/record/1009074
_version_ 1780911815397474304
author Clerbaux, Barbara
Elgammal, Sherif
Mahmoud, Tariq
Marage, Pierre Edouard
author_facet Clerbaux, Barbara
Elgammal, Sherif
Mahmoud, Tariq
Marage, Pierre Edouard
author_sort Clerbaux, Barbara
collection CERN
description This note presents a study of the response of the CMS electromagnetic calorimeter ECAL to high energy electrons and photons (from 500 to 4000 GeV), using the full simulation of the CMS detector. The longitudinal containment and the lateral extension of high energy showers are discussed, and energy and eta dependent correction factors F(E_meas, eta), where E_meas = E_ECAL + E_HCAL, are determined in order to reconstruct the incident particle energy, using the energies measured in the ECAL and in the hadronic calorimeter HCAL. For ECAL barrel crystals with energy deposit higher than 1700 GeV, improvements are proposed to techniques aimed at correcting for the effects of electronics saturation.
id cern-1009074
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-10090742019-09-30T06:29:59Zhttp://cds.cern.ch/record/1009074engClerbaux, BarbaraElgammal, SherifMahmoud, TariqMarage, Pierre EdouardSaturation and Energy Corrections for TeV Electrons and PhotonsDetectors and Experimental TechniquesThis note presents a study of the response of the CMS electromagnetic calorimeter ECAL to high energy electrons and photons (from 500 to 4000 GeV), using the full simulation of the CMS detector. The longitudinal containment and the lateral extension of high energy showers are discussed, and energy and eta dependent correction factors F(E_meas, eta), where E_meas = E_ECAL + E_HCAL, are determined in order to reconstruct the incident particle energy, using the energies measured in the ECAL and in the hadronic calorimeter HCAL. For ECAL barrel crystals with energy deposit higher than 1700 GeV, improvements are proposed to techniques aimed at correcting for the effects of electronics saturation.CMS-NOTE-2006-149oai:cds.cern.ch:10090742006-12-18
spellingShingle Detectors and Experimental Techniques
Clerbaux, Barbara
Elgammal, Sherif
Mahmoud, Tariq
Marage, Pierre Edouard
Saturation and Energy Corrections for TeV Electrons and Photons
title Saturation and Energy Corrections for TeV Electrons and Photons
title_full Saturation and Energy Corrections for TeV Electrons and Photons
title_fullStr Saturation and Energy Corrections for TeV Electrons and Photons
title_full_unstemmed Saturation and Energy Corrections for TeV Electrons and Photons
title_short Saturation and Energy Corrections for TeV Electrons and Photons
title_sort saturation and energy corrections for tev electrons and photons
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1009074
work_keys_str_mv AT clerbauxbarbara saturationandenergycorrectionsfortevelectronsandphotons
AT elgammalsherif saturationandenergycorrectionsfortevelectronsandphotons
AT mahmoudtariq saturationandenergycorrectionsfortevelectronsandphotons
AT maragepierreedouard saturationandenergycorrectionsfortevelectronsandphotons