Cargando…

Long-term geometry stability of ATLAS MDT chambers studied with a high-precision X-ray tomograph

The CERN X-ray tomograph measures the 2-dimensional position of MDT chamber wires with a total uncertainty of less than 5 microns. This dedicated facility has assured consistent production quality of chamber geometries over the five year construction phase between 2000 and 2005 by sampling about 15%...

Descripción completa

Detalles Bibliográficos
Autores principales: Schuh, S, Kowarik, G, Marchesotti, M, Da Silva, R, Voss, R, Zhuravlov, V
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:http://cds.cern.ch/record/1020043
_version_ 1780912081556471808
author Schuh, S
Kowarik, G
Marchesotti, M
Da Silva, R
Voss, R
Zhuravlov, V
author_facet Schuh, S
Kowarik, G
Marchesotti, M
Da Silva, R
Voss, R
Zhuravlov, V
author_sort Schuh, S
collection CERN
description The CERN X-ray tomograph measures the 2-dimensional position of MDT chamber wires with a total uncertainty of less than 5 microns. This dedicated facility has assured consistent production quality of chamber geometries over the five year construction phase between 2000 and 2005 by sampling about 15% of the total 1200 MDT chambers produced. Part of the tomograph measurement capacity has been used to perform re-measurements of selected chambers. We briefly describe the tomograph facility and its capabilities, present a global view of the mechanical accuracy and consistency of the full MDT production and then summarize the results obtained from the chamber re-measurements and discuss their possible implications for long-term MDT geometry stability.
id cern-1020043
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-10200432019-09-30T06:29:59Zhttp://cds.cern.ch/record/1020043engSchuh, SKowarik, GMarchesotti, MDa Silva, RVoss, RZhuravlov, VLong-term geometry stability of ATLAS MDT chambers studied with a high-precision X-ray tomographDetectors and Experimental TechniquesThe CERN X-ray tomograph measures the 2-dimensional position of MDT chamber wires with a total uncertainty of less than 5 microns. This dedicated facility has assured consistent production quality of chamber geometries over the five year construction phase between 2000 and 2005 by sampling about 15% of the total 1200 MDT chambers produced. Part of the tomograph measurement capacity has been used to perform re-measurements of selected chambers. We briefly describe the tomograph facility and its capabilities, present a global view of the mechanical accuracy and consistency of the full MDT production and then summarize the results obtained from the chamber re-measurements and discuss their possible implications for long-term MDT geometry stability.oai:cds.cern.ch:10200432006
spellingShingle Detectors and Experimental Techniques
Schuh, S
Kowarik, G
Marchesotti, M
Da Silva, R
Voss, R
Zhuravlov, V
Long-term geometry stability of ATLAS MDT chambers studied with a high-precision X-ray tomograph
title Long-term geometry stability of ATLAS MDT chambers studied with a high-precision X-ray tomograph
title_full Long-term geometry stability of ATLAS MDT chambers studied with a high-precision X-ray tomograph
title_fullStr Long-term geometry stability of ATLAS MDT chambers studied with a high-precision X-ray tomograph
title_full_unstemmed Long-term geometry stability of ATLAS MDT chambers studied with a high-precision X-ray tomograph
title_short Long-term geometry stability of ATLAS MDT chambers studied with a high-precision X-ray tomograph
title_sort long-term geometry stability of atlas mdt chambers studied with a high-precision x-ray tomograph
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1020043
work_keys_str_mv AT schuhs longtermgeometrystabilityofatlasmdtchambersstudiedwithahighprecisionxraytomograph
AT kowarikg longtermgeometrystabilityofatlasmdtchambersstudiedwithahighprecisionxraytomograph
AT marchesottim longtermgeometrystabilityofatlasmdtchambersstudiedwithahighprecisionxraytomograph
AT dasilvar longtermgeometrystabilityofatlasmdtchambersstudiedwithahighprecisionxraytomograph
AT vossr longtermgeometrystabilityofatlasmdtchambersstudiedwithahighprecisionxraytomograph
AT zhuravlovv longtermgeometrystabilityofatlasmdtchambersstudiedwithahighprecisionxraytomograph