High Voltage System for the CMS Electromagnetic Calorimeter
The CMS electromagnetic calorimeter (ECAL) is made of about 75000 lead tungstate crystals. The 61200 crystals of the barrel part are read by avalanche photodiodes (APD) with internal amplification of the signal. Since the gain strongly depends on the bias voltage, the APDs require a very stable powe...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1027033 |
_version_ | 1780912242695340032 |
---|---|
author | Bartoloni, Alessandro Barone, Luciano Cavallari, Francesca Dafinei, Ioan Del Re, Daniele Diemoz, Marcella Guerra, Sergio Longo, Egidio Meridiani, Paolo Organtini, Giovanni Palma, Alessandro Paramatti, Riccardo Pellegrino, Fabio Rahatlou, Shahram Rovelli, Chiara Santanastasio, Francesco |
author_facet | Bartoloni, Alessandro Barone, Luciano Cavallari, Francesca Dafinei, Ioan Del Re, Daniele Diemoz, Marcella Guerra, Sergio Longo, Egidio Meridiani, Paolo Organtini, Giovanni Palma, Alessandro Paramatti, Riccardo Pellegrino, Fabio Rahatlou, Shahram Rovelli, Chiara Santanastasio, Francesco |
author_sort | Bartoloni, Alessandro |
collection | CERN |
description | The CMS electromagnetic calorimeter (ECAL) is made of about 75000 lead tungstate crystals. The 61200 crystals of the barrel part are read by avalanche photodiodes (APD) with internal amplification of the signal. Since the gain strongly depends on the bias voltage, the APDs require a very stable power supply system. To preserve the high energy resolution of the calorimeter, a stability of the bias voltage of the order of 10^-4 is required over several months, a typical interval between absolute calibrations of the full read-out chain with physics events. This paper describes the High Voltage power supply system developed for CMS ECAL and its performances as measured in laboratory tests and during test-beam operations of several modules of the calorimeter. |
id | cern-1027033 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10270332019-09-30T06:29:59Zhttp://cds.cern.ch/record/1027033engBartoloni, AlessandroBarone, LucianoCavallari, FrancescaDafinei, IoanDel Re, DanieleDiemoz, MarcellaGuerra, SergioLongo, EgidioMeridiani, PaoloOrgantini, GiovanniPalma, AlessandroParamatti, RiccardoPellegrino, FabioRahatlou, ShahramRovelli, ChiaraSantanastasio, FrancescoHigh Voltage System for the CMS Electromagnetic CalorimeterDetectors and Experimental TechniquesThe CMS electromagnetic calorimeter (ECAL) is made of about 75000 lead tungstate crystals. The 61200 crystals of the barrel part are read by avalanche photodiodes (APD) with internal amplification of the signal. Since the gain strongly depends on the bias voltage, the APDs require a very stable power supply system. To preserve the high energy resolution of the calorimeter, a stability of the bias voltage of the order of 10^-4 is required over several months, a typical interval between absolute calibrations of the full read-out chain with physics events. This paper describes the High Voltage power supply system developed for CMS ECAL and its performances as measured in laboratory tests and during test-beam operations of several modules of the calorimeter.CMS-NOTE-2007-009oai:cds.cern.ch:10270332007-04-02 |
spellingShingle | Detectors and Experimental Techniques Bartoloni, Alessandro Barone, Luciano Cavallari, Francesca Dafinei, Ioan Del Re, Daniele Diemoz, Marcella Guerra, Sergio Longo, Egidio Meridiani, Paolo Organtini, Giovanni Palma, Alessandro Paramatti, Riccardo Pellegrino, Fabio Rahatlou, Shahram Rovelli, Chiara Santanastasio, Francesco High Voltage System for the CMS Electromagnetic Calorimeter |
title | High Voltage System for the CMS Electromagnetic Calorimeter |
title_full | High Voltage System for the CMS Electromagnetic Calorimeter |
title_fullStr | High Voltage System for the CMS Electromagnetic Calorimeter |
title_full_unstemmed | High Voltage System for the CMS Electromagnetic Calorimeter |
title_short | High Voltage System for the CMS Electromagnetic Calorimeter |
title_sort | high voltage system for the cms electromagnetic calorimeter |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1027033 |
work_keys_str_mv | AT bartolonialessandro highvoltagesystemforthecmselectromagneticcalorimeter AT baroneluciano highvoltagesystemforthecmselectromagneticcalorimeter AT cavallarifrancesca highvoltagesystemforthecmselectromagneticcalorimeter AT dafineiioan highvoltagesystemforthecmselectromagneticcalorimeter AT delredaniele highvoltagesystemforthecmselectromagneticcalorimeter AT diemozmarcella highvoltagesystemforthecmselectromagneticcalorimeter AT guerrasergio highvoltagesystemforthecmselectromagneticcalorimeter AT longoegidio highvoltagesystemforthecmselectromagneticcalorimeter AT meridianipaolo highvoltagesystemforthecmselectromagneticcalorimeter AT organtinigiovanni highvoltagesystemforthecmselectromagneticcalorimeter AT palmaalessandro highvoltagesystemforthecmselectromagneticcalorimeter AT paramattiriccardo highvoltagesystemforthecmselectromagneticcalorimeter AT pellegrinofabio highvoltagesystemforthecmselectromagneticcalorimeter AT rahatloushahram highvoltagesystemforthecmselectromagneticcalorimeter AT rovellichiara highvoltagesystemforthecmselectromagneticcalorimeter AT santanastasiofrancesco highvoltagesystemforthecmselectromagneticcalorimeter |