Cargando…
Performance of CMS ECAL Very Front End Electronics
We report the results of tests of 12880 Very Front End (VFE) readout cards for the barrel of the CMS electromagnetic calorimeter. A thorough test sequence was applied to each card including power-on test, burn-in and final calibration. Cards failing the tests were at the few per mille level. The res...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-2007-001.174 http://cds.cern.ch/record/1027433 |
Sumario: | We report the results of tests of 12880 Very Front End (VFE) readout cards for the barrel of the CMS electromagnetic calorimeter. A thorough test sequence was applied to each card including power-on test, burn-in and final calibration. Cards failing the tests were at the few per mille level. The results prove the very high quality of the VFE cards. |
---|