Performance Analysis of a Fast Digital Integrator for Magnetic Field Measurements at CERN

A Fast Digital Integrator (FDI) has been designed at CERN for increasing performance of state-of-art instruments analyzing superconducting magnets in particle accelerators. In particular, in flux measurement, a bandwidth up to 50-100 kHz and an accuracy of 10 ppm has to be targeted. In this paper, b...

Descripción completa

Detalles Bibliográficos
Autores principales: Arpaia, P, Bottura, L, Masi, A, Spiezia, G
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:http://cds.cern.ch/record/1027514
_version_ 1780912279976411136
author Arpaia, P
Bottura, L
Masi, A
Spiezia, G
author_facet Arpaia, P
Bottura, L
Masi, A
Spiezia, G
author_sort Arpaia, P
collection CERN
description A Fast Digital Integrator (FDI) has been designed at CERN for increasing performance of state-of-art instruments analyzing superconducting magnets in particle accelerators. In particular, in flux measurement, a bandwidth up to 50-100 kHz and an accuracy of 10 ppm has to be targeted. In this paper, basic concepts and architecture of the developed FDI are highlighted. Numerical metrological analysis of the instrument performance is shown, by focusing both on deterministic errors and on uncertainty in time and amplitude domains.
id cern-1027514
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
record_format invenio
spelling cern-10275142019-09-30T06:29:59Zhttp://cds.cern.ch/record/1027514engArpaia, PBottura, LMasi, ASpiezia, GPerformance Analysis of a Fast Digital Integrator for Magnetic Field Measurements at CERNAccelerators and Storage RingsA Fast Digital Integrator (FDI) has been designed at CERN for increasing performance of state-of-art instruments analyzing superconducting magnets in particle accelerators. In particular, in flux measurement, a bandwidth up to 50-100 kHz and an accuracy of 10 ppm has to be targeted. In this paper, basic concepts and architecture of the developed FDI are highlighted. Numerical metrological analysis of the instrument performance is shown, by focusing both on deterministic errors and on uncertainty in time and amplitude domains.CERN-AT-2007-015-MTMoai:cds.cern.ch:10275142007-03-26
spellingShingle Accelerators and Storage Rings
Arpaia, P
Bottura, L
Masi, A
Spiezia, G
Performance Analysis of a Fast Digital Integrator for Magnetic Field Measurements at CERN
title Performance Analysis of a Fast Digital Integrator for Magnetic Field Measurements at CERN
title_full Performance Analysis of a Fast Digital Integrator for Magnetic Field Measurements at CERN
title_fullStr Performance Analysis of a Fast Digital Integrator for Magnetic Field Measurements at CERN
title_full_unstemmed Performance Analysis of a Fast Digital Integrator for Magnetic Field Measurements at CERN
title_short Performance Analysis of a Fast Digital Integrator for Magnetic Field Measurements at CERN
title_sort performance analysis of a fast digital integrator for magnetic field measurements at cern
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1027514
work_keys_str_mv AT arpaiap performanceanalysisofafastdigitalintegratorformagneticfieldmeasurementsatcern
AT bottural performanceanalysisofafastdigitalintegratorformagneticfieldmeasurementsatcern
AT masia performanceanalysisofafastdigitalintegratorformagneticfieldmeasurementsatcern
AT spieziag performanceanalysisofafastdigitalintegratorformagneticfieldmeasurementsatcern