The ALICE Silicon Pixel Detector Control system and online calibration tools
The ALICE Silicon Pixel Detector (SPD) contains nearly 107 hybrid pixel cells. The operation of the SPD requires online control and monitoring of some 2000 parameters and » 50000DACs. Information for each channel is stored in a configuration database. Timing and data management (» 6GB of raw data ea...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/2/04/P04008 https://dx.doi.org/10.5170/CERN-2007-001.356 http://cds.cern.ch/record/1028138 |
_version_ | 1780912317106487296 |
---|---|
author | Cali, I A Caselle, M Ceresa, S Kluge, A Krivda, M Riedler, P Tydesjo, H Torcato De Matos, C |
author_facet | Cali, I A Caselle, M Ceresa, S Kluge, A Krivda, M Riedler, P Tydesjo, H Torcato De Matos, C |
author_sort | Cali, I A |
collection | CERN |
description | The ALICE Silicon Pixel Detector (SPD) contains nearly 107 hybrid pixel cells. The operation of the SPD requires online control and monitoring of some 2000 parameters and » 50000DACs. Information for each channel is stored in a configuration database. Timing and data management (» 6GB of raw data each calibration) are critical issues. An overview of the SPD electronics read out chain and of the detector control system is given with a detailed description of the front-end controls and the calibration strategy. The status of commissioning and a preliminary evaluation of detector performance are presented. |
id | cern-1028138 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
publisher | CERN |
record_format | invenio |
spelling | cern-10281382019-09-30T06:29:59Zdoi:10.1088/1748-0221/2/04/P04008doi:10.5170/CERN-2007-001.356http://cds.cern.ch/record/1028138engCali, I ACaselle, MCeresa, SKluge, AKrivda, MRiedler, PTydesjo, HTorcato De Matos, CThe ALICE Silicon Pixel Detector Control system and online calibration toolsDetectors and Experimental TechniquesThe ALICE Silicon Pixel Detector (SPD) contains nearly 107 hybrid pixel cells. The operation of the SPD requires online control and monitoring of some 2000 parameters and » 50000DACs. Information for each channel is stored in a configuration database. Timing and data management (» 6GB of raw data each calibration) are critical issues. An overview of the SPD electronics read out chain and of the detector control system is given with a detailed description of the front-end controls and the calibration strategy. The status of commissioning and a preliminary evaluation of detector performance are presented.CERNoai:cds.cern.ch:10281382007 |
spellingShingle | Detectors and Experimental Techniques Cali, I A Caselle, M Ceresa, S Kluge, A Krivda, M Riedler, P Tydesjo, H Torcato De Matos, C The ALICE Silicon Pixel Detector Control system and online calibration tools |
title | The ALICE Silicon Pixel Detector Control system and online calibration tools |
title_full | The ALICE Silicon Pixel Detector Control system and online calibration tools |
title_fullStr | The ALICE Silicon Pixel Detector Control system and online calibration tools |
title_full_unstemmed | The ALICE Silicon Pixel Detector Control system and online calibration tools |
title_short | The ALICE Silicon Pixel Detector Control system and online calibration tools |
title_sort | alice silicon pixel detector control system and online calibration tools |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/2/04/P04008 https://dx.doi.org/10.5170/CERN-2007-001.356 http://cds.cern.ch/record/1028138 |
work_keys_str_mv | AT caliia thealicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT casellem thealicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT ceresas thealicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT klugea thealicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT krivdam thealicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT riedlerp thealicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT tydesjoh thealicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT torcatodematosc thealicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT caliia alicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT casellem alicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT ceresas alicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT klugea alicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT krivdam alicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT riedlerp alicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT tydesjoh alicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools AT torcatodematosc alicesiliconpixeldetectorcontrolsystemandonlinecalibrationtools |