Quality assurance for CMS Tracker LV and HV Power Supplies
This work describes the quality assurance measurements that have been carried out on about 2000 Power Supply Units produced in CAEN technology for the CMS Silicon Tracker Detector. The automate procedure and the characteristics of the dedicated Test Fixture developed for this activity are described...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-2007-001.369 http://cds.cern.ch/record/1028141 |
_version_ | 1780912317572055040 |
---|---|
author | Costa, Marco Peruzzo, A Sertoli, M Trapani, P Periale, L Isabella, L Landi, C Lucchesi, A |
author_facet | Costa, Marco Peruzzo, A Sertoli, M Trapani, P Periale, L Isabella, L Landi, C Lucchesi, A |
author_sort | Costa, Marco |
collection | CERN |
description | This work describes the quality assurance measurements that have been carried out on about 2000 Power Supply Units produced in CAEN technology for the CMS Silicon Tracker Detector. The automate procedure and the characteristics of the dedicated Test Fixture developed for this activity are described in details. Magnetic field tolerance and radiation hardness of Tracker power supply units is also discussed at length. |
id | cern-1028141 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
publisher | CERN |
record_format | invenio |
spelling | cern-10281412019-09-30T06:29:59Zdoi:10.5170/CERN-2007-001.369http://cds.cern.ch/record/1028141engCosta, MarcoPeruzzo, ASertoli, MTrapani, PPeriale, LIsabella, LLandi, CLucchesi, AQuality assurance for CMS Tracker LV and HV Power SuppliesDetectors and Experimental TechniquesThis work describes the quality assurance measurements that have been carried out on about 2000 Power Supply Units produced in CAEN technology for the CMS Silicon Tracker Detector. The automate procedure and the characteristics of the dedicated Test Fixture developed for this activity are described in details. Magnetic field tolerance and radiation hardness of Tracker power supply units is also discussed at length.CERNoai:cds.cern.ch:10281412007 |
spellingShingle | Detectors and Experimental Techniques Costa, Marco Peruzzo, A Sertoli, M Trapani, P Periale, L Isabella, L Landi, C Lucchesi, A Quality assurance for CMS Tracker LV and HV Power Supplies |
title | Quality assurance for CMS Tracker LV and HV Power Supplies |
title_full | Quality assurance for CMS Tracker LV and HV Power Supplies |
title_fullStr | Quality assurance for CMS Tracker LV and HV Power Supplies |
title_full_unstemmed | Quality assurance for CMS Tracker LV and HV Power Supplies |
title_short | Quality assurance for CMS Tracker LV and HV Power Supplies |
title_sort | quality assurance for cms tracker lv and hv power supplies |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.5170/CERN-2007-001.369 http://cds.cern.ch/record/1028141 |
work_keys_str_mv | AT costamarco qualityassuranceforcmstrackerlvandhvpowersupplies AT peruzzoa qualityassuranceforcmstrackerlvandhvpowersupplies AT sertolim qualityassuranceforcmstrackerlvandhvpowersupplies AT trapanip qualityassuranceforcmstrackerlvandhvpowersupplies AT perialel qualityassuranceforcmstrackerlvandhvpowersupplies AT isabellal qualityassuranceforcmstrackerlvandhvpowersupplies AT landic qualityassuranceforcmstrackerlvandhvpowersupplies AT lucchesia qualityassuranceforcmstrackerlvandhvpowersupplies |