Cargando…

Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET

We have studied the performance of two multi-pixel Geiger-mode APDs (recently developed by the Centre of Perspective Technologies and Apparatus (CPTA) in Moscow) with 1×1 mm2 and 3×3 mm2 sensitive area as a readout for LSO and LYSO scintillator crystals. Energy and timing spectra were measured using...

Descripción completa

Detalles Bibliográficos
Autores principales: Musienko, Yuri, Auffray, Etiennette, Lecoq, Paul, Reucroft, Stephen, Swain, John, Trummer, Julia
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2006.10.109
http://cds.cern.ch/record/1035257
_version_ 1780912457463627776
author Musienko, Yuri
Auffray, Etiennette
Lecoq, Paul
Reucroft, Stephen
Swain, John
Trummer, Julia
author_facet Musienko, Yuri
Auffray, Etiennette
Lecoq, Paul
Reucroft, Stephen
Swain, John
Trummer, Julia
author_sort Musienko, Yuri
collection CERN
description We have studied the performance of two multi-pixel Geiger-mode APDs (recently developed by the Centre of Perspective Technologies and Apparatus (CPTA) in Moscow) with 1×1 mm2 and 3×3 mm2 sensitive area as a readout for LSO and LYSO scintillator crystals. Energy and timing spectra were measured using a 22Na γ-source. The results of this study allow us to conclude that this photodetector is a very promising candidate for PET applications.
id cern-1035257
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
record_format invenio
spelling cern-10352572019-09-30T06:29:59Zdoi:10.1016/j.nima.2006.10.109http://cds.cern.ch/record/1035257engMusienko, YuriAuffray, EtiennetteLecoq, PaulReucroft, StephenSwain, JohnTrummer, JuliaStudy of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PETHealth Physics and Radiation EffectsWe have studied the performance of two multi-pixel Geiger-mode APDs (recently developed by the Centre of Perspective Technologies and Apparatus (CPTA) in Moscow) with 1×1 mm2 and 3×3 mm2 sensitive area as a readout for LSO and LYSO scintillator crystals. Energy and timing spectra were measured using a 22Na γ-source. The results of this study allow us to conclude that this photodetector is a very promising candidate for PET applications.oai:cds.cern.ch:10352572007
spellingShingle Health Physics and Radiation Effects
Musienko, Yuri
Auffray, Etiennette
Lecoq, Paul
Reucroft, Stephen
Swain, John
Trummer, Julia
Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET
title Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET
title_full Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET
title_fullStr Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET
title_full_unstemmed Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET
title_short Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET
title_sort study of multi-pixel geiger-mode avalanche photodiodes as a read-out for pet
topic Health Physics and Radiation Effects
url https://dx.doi.org/10.1016/j.nima.2006.10.109
http://cds.cern.ch/record/1035257
work_keys_str_mv AT musienkoyuri studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet
AT auffrayetiennette studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet
AT lecoqpaul studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet
AT reucroftstephen studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet
AT swainjohn studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet
AT trummerjulia studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet