Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET
We have studied the performance of two multi-pixel Geiger-mode APDs (recently developed by the Centre of Perspective Technologies and Apparatus (CPTA) in Moscow) with 1×1 mm2 and 3×3 mm2 sensitive area as a readout for LSO and LYSO scintillator crystals. Energy and timing spectra were measured using...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2006.10.109 http://cds.cern.ch/record/1035257 |
_version_ | 1780912457463627776 |
---|---|
author | Musienko, Yuri Auffray, Etiennette Lecoq, Paul Reucroft, Stephen Swain, John Trummer, Julia |
author_facet | Musienko, Yuri Auffray, Etiennette Lecoq, Paul Reucroft, Stephen Swain, John Trummer, Julia |
author_sort | Musienko, Yuri |
collection | CERN |
description | We have studied the performance of two multi-pixel Geiger-mode APDs (recently developed by the Centre of Perspective Technologies and Apparatus (CPTA) in Moscow) with 1×1 mm2 and 3×3 mm2 sensitive area as a readout for LSO and LYSO scintillator crystals. Energy and timing spectra were measured using a 22Na γ-source. The results of this study allow us to conclude that this photodetector is a very promising candidate for PET applications. |
id | cern-1035257 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10352572019-09-30T06:29:59Zdoi:10.1016/j.nima.2006.10.109http://cds.cern.ch/record/1035257engMusienko, YuriAuffray, EtiennetteLecoq, PaulReucroft, StephenSwain, JohnTrummer, JuliaStudy of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PETHealth Physics and Radiation EffectsWe have studied the performance of two multi-pixel Geiger-mode APDs (recently developed by the Centre of Perspective Technologies and Apparatus (CPTA) in Moscow) with 1×1 mm2 and 3×3 mm2 sensitive area as a readout for LSO and LYSO scintillator crystals. Energy and timing spectra were measured using a 22Na γ-source. The results of this study allow us to conclude that this photodetector is a very promising candidate for PET applications.oai:cds.cern.ch:10352572007 |
spellingShingle | Health Physics and Radiation Effects Musienko, Yuri Auffray, Etiennette Lecoq, Paul Reucroft, Stephen Swain, John Trummer, Julia Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET |
title | Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET |
title_full | Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET |
title_fullStr | Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET |
title_full_unstemmed | Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET |
title_short | Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET |
title_sort | study of multi-pixel geiger-mode avalanche photodiodes as a read-out for pet |
topic | Health Physics and Radiation Effects |
url | https://dx.doi.org/10.1016/j.nima.2006.10.109 http://cds.cern.ch/record/1035257 |
work_keys_str_mv | AT musienkoyuri studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet AT auffrayetiennette studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet AT lecoqpaul studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet AT reucroftstephen studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet AT swainjohn studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet AT trummerjulia studyofmultipixelgeigermodeavalanchephotodiodesasareadoutforpet |