Cargando…
High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix
We describe a novel method to extract the axial coordinate from a matrix of long axially oriented crystals, which is based on wavelength shifting plastic strips. The method allows building compact 3-D axial gamma detector modules for PET scanners with excellent 3-dimensional spatial, timing and ener...
Autores principales: | , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2007.06.107 http://cds.cern.ch/record/1036209 |
_version_ | 1780912525523550208 |
---|---|
author | Braem, André Chesi, Enrico Guido Joram, C Séguinot, Jacques Weilhammer, P De Leo, R Nappi, E Lustermann, W Schinzel, D Johnson, I Renker, D Albrecht, S |
author_facet | Braem, André Chesi, Enrico Guido Joram, C Séguinot, Jacques Weilhammer, P De Leo, R Nappi, E Lustermann, W Schinzel, D Johnson, I Renker, D Albrecht, S |
author_sort | Braem, André |
collection | CERN |
description | We describe a novel method to extract the axial coordinate from a matrix of long axially oriented crystals, which is based on wavelength shifting plastic strips. The method allows building compact 3-D axial gamma detector modules for PET scanners with excellent 3-dimensional spatial, timing and energy resolution while keeping the number of readout channels reasonably low. A voxel resolution of about 10 mm3 is expected. We assess the performance of the method in two independent ways, using classical PMTs and G-APDs to read out the LYSO (LSO) scintillation crystals and the wavelength shifting strips. We observe yields in excess of 35 photoelectrons from the strips for a 511 keV gamma and reconstruct the axial coordinate with a precision of about 2.5 mm (FWHM). |
id | cern-1036209 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10362092019-09-30T06:29:59Zdoi:10.1016/j.nima.2007.06.107http://cds.cern.ch/record/1036209engBraem, AndréChesi, Enrico GuidoJoram, CSéguinot, JacquesWeilhammer, PDe Leo, RNappi, ELustermann, WSchinzel, DJohnson, IRenker, DAlbrecht, SHigh Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip MatrixDetectors and Experimental TechniquesHealth Physics and Radiation EffectsWe describe a novel method to extract the axial coordinate from a matrix of long axially oriented crystals, which is based on wavelength shifting plastic strips. The method allows building compact 3-D axial gamma detector modules for PET scanners with excellent 3-dimensional spatial, timing and energy resolution while keeping the number of readout channels reasonably low. A voxel resolution of about 10 mm3 is expected. We assess the performance of the method in two independent ways, using classical PMTs and G-APDs to read out the LYSO (LSO) scintillation crystals and the wavelength shifting strips. We observe yields in excess of 35 photoelectrons from the strips for a 511 keV gamma and reconstruct the axial coordinate with a precision of about 2.5 mm (FWHM).CERN-PH-EP-2007-013oai:cds.cern.ch:10362092007-05-09 |
spellingShingle | Detectors and Experimental Techniques Health Physics and Radiation Effects Braem, André Chesi, Enrico Guido Joram, C Séguinot, Jacques Weilhammer, P De Leo, R Nappi, E Lustermann, W Schinzel, D Johnson, I Renker, D Albrecht, S High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix |
title | High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix |
title_full | High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix |
title_fullStr | High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix |
title_full_unstemmed | High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix |
title_short | High Precision Axial Coordinate Readout for an Axial 3-D PET Detector Module using a Wave Length Shifter Strip Matrix |
title_sort | high precision axial coordinate readout for an axial 3-d pet detector module using a wave length shifter strip matrix |
topic | Detectors and Experimental Techniques Health Physics and Radiation Effects |
url | https://dx.doi.org/10.1016/j.nima.2007.06.107 http://cds.cern.ch/record/1036209 |
work_keys_str_mv | AT braemandre highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT chesienricoguido highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT joramc highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT seguinotjacques highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT weilhammerp highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT deleor highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT nappie highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT lustermannw highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT schinzeld highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT johnsoni highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT renkerd highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix AT albrechts highprecisionaxialcoordinatereadoutforanaxial3dpetdetectormoduleusingawavelengthshifterstripmatrix |