Cargando…
A monitoring method for the Low Voltage Power Supply modules of the ATLAS Tile Calorimeter
We present a method for testing the operational stability of Low Voltage Power Supply modules of the ATLAS Tile Calorimeter, based on a self-consistent determination of the stability criteria. The recorded voltage, current, and temperature values of each module are retrieved from the Oracle database...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1046807 |
_version_ | 1780912768287768576 |
---|---|
author | Vellidis, C Arabidze, G Giokaris, N Guimarães-Ferreira, F Roy, D Vichou, I |
author_facet | Vellidis, C Arabidze, G Giokaris, N Guimarães-Ferreira, F Roy, D Vichou, I |
author_sort | Vellidis, C |
collection | CERN |
description | We present a method for testing the operational stability of Low Voltage Power Supply modules of the ATLAS Tile Calorimeter, based on a self-consistent determination of the stability criteria. The recorded voltage, current, and temperature values of each module are retrieved from the Oracle database for a long and smooth running period and their mean and RMS values over that period are determined, as well as their average recording rates, by taking into account the â??smoothingâ?? procedure which is applied during data recording to reduce data storage. The average behavior of the ensemble of all modules is determined from those time-integrated quantities and the modules are then tested one-by-one by comparing with the ensemble averages. The proposed method is tested for all Long Barrel modules operated during April of 2007. |
id | cern-1046807 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10468072019-09-30T06:29:59Zhttp://cds.cern.ch/record/1046807engVellidis, CArabidze, GGiokaris, NGuimarães-Ferreira, FRoy, DVichou, IA monitoring method for the Low Voltage Power Supply modules of the ATLAS Tile CalorimeterDetectors and Experimental TechniquesWe present a method for testing the operational stability of Low Voltage Power Supply modules of the ATLAS Tile Calorimeter, based on a self-consistent determination of the stability criteria. The recorded voltage, current, and temperature values of each module are retrieved from the Oracle database for a long and smooth running period and their mean and RMS values over that period are determined, as well as their average recording rates, by taking into account the â??smoothingâ?? procedure which is applied during data recording to reduce data storage. The average behavior of the ensemble of all modules is determined from those time-integrated quantities and the modules are then tested one-by-one by comparing with the ensemble averages. The proposed method is tested for all Long Barrel modules operated during April of 2007.ATL-TILECAL-PUB-2007-009ATL-COM-TILECAL-2007-014oai:cds.cern.ch:10468072007-07-13 |
spellingShingle | Detectors and Experimental Techniques Vellidis, C Arabidze, G Giokaris, N Guimarães-Ferreira, F Roy, D Vichou, I A monitoring method for the Low Voltage Power Supply modules of the ATLAS Tile Calorimeter |
title | A monitoring method for the Low Voltage Power Supply modules of the ATLAS Tile Calorimeter |
title_full | A monitoring method for the Low Voltage Power Supply modules of the ATLAS Tile Calorimeter |
title_fullStr | A monitoring method for the Low Voltage Power Supply modules of the ATLAS Tile Calorimeter |
title_full_unstemmed | A monitoring method for the Low Voltage Power Supply modules of the ATLAS Tile Calorimeter |
title_short | A monitoring method for the Low Voltage Power Supply modules of the ATLAS Tile Calorimeter |
title_sort | monitoring method for the low voltage power supply modules of the atlas tile calorimeter |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1046807 |
work_keys_str_mv | AT vellidisc amonitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT arabidzeg amonitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT giokarisn amonitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT guimaraesferreiraf amonitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT royd amonitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT vichoui amonitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT vellidisc monitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT arabidzeg monitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT giokarisn monitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT guimaraesferreiraf monitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT royd monitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter AT vichoui monitoringmethodforthelowvoltagepowersupplymodulesoftheatlastilecalorimeter |