Cargando…
The intercalibration of the CMS electromagnetic calorimeter at the test beam
During summer 2006, 9 supermodules of the CMS electromagnetic calorimeter (ECAL) have been exposed to an electron beam at the CERN SPS north area facility. Each supermodule contains 1700 crystals. The intercalibration coefficients of the different channels have been measured for each supermodule. Th...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1049928 |
_version_ | 1780912844849545216 |
---|---|
author | Govoni, P Tancini, V |
author_facet | Govoni, P Tancini, V |
author_sort | Govoni, P |
collection | CERN |
description | During summer 2006, 9 supermodules of the CMS electromagnetic calorimeter (ECAL) have been exposed to an electron beam at the CERN SPS north area facility. Each supermodule contains 1700 crystals. The intercalibration coefficients of the different channels have been measured for each supermodule. The reproducibility of the intercalibration has been tested by measuring a supermodule twice. The intercalibration coefficients obtained in the electron beam have also been compared with those obtained with cosmic ray muons. |
id | cern-1049928 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10499282019-09-30T06:29:59Zhttp://cds.cern.ch/record/1049928engGovoni, PTancini, VThe intercalibration of the CMS electromagnetic calorimeter at the test beamDetectors and Experimental TechniquesDuring summer 2006, 9 supermodules of the CMS electromagnetic calorimeter (ECAL) have been exposed to an electron beam at the CERN SPS north area facility. Each supermodule contains 1700 crystals. The intercalibration coefficients of the different channels have been measured for each supermodule. The reproducibility of the intercalibration has been tested by measuring a supermodule twice. The intercalibration coefficients obtained in the electron beam have also been compared with those obtained with cosmic ray muons.CMS-CR-2007-037oai:cds.cern.ch:10499282007 |
spellingShingle | Detectors and Experimental Techniques Govoni, P Tancini, V The intercalibration of the CMS electromagnetic calorimeter at the test beam |
title | The intercalibration of the CMS electromagnetic calorimeter at the test beam |
title_full | The intercalibration of the CMS electromagnetic calorimeter at the test beam |
title_fullStr | The intercalibration of the CMS electromagnetic calorimeter at the test beam |
title_full_unstemmed | The intercalibration of the CMS electromagnetic calorimeter at the test beam |
title_short | The intercalibration of the CMS electromagnetic calorimeter at the test beam |
title_sort | intercalibration of the cms electromagnetic calorimeter at the test beam |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1049928 |
work_keys_str_mv | AT govonip theintercalibrationofthecmselectromagneticcalorimeteratthetestbeam AT tanciniv theintercalibrationofthecmselectromagneticcalorimeteratthetestbeam AT govonip intercalibrationofthecmselectromagneticcalorimeteratthetestbeam AT tanciniv intercalibrationofthecmselectromagneticcalorimeteratthetestbeam |