Cargando…

The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters

The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cry...

Descripción completa

Detalles Bibliográficos
Autores principales: Botchev, B., Finocchiaro, G., Hoffman, J., McCarthy, R.L., Rijssenbeek, M., Steffens, J., Talalaevskii, A., Thioye, M., Zdrazil, M., Farrell, J., Kane, S.
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/2/10/T10002
http://cds.cern.ch/record/1055349
_version_ 1780913031514947584
author Botchev, B.
Finocchiaro, G.
Hoffman, J.
McCarthy, R.L.
Rijssenbeek, M.
Steffens, J.
Talalaevskii, A.
Thioye, M.
Zdrazil, M.
Farrell, J.
Kane, S.
author_facet Botchev, B.
Finocchiaro, G.
Hoffman, J.
McCarthy, R.L.
Rijssenbeek, M.
Steffens, J.
Talalaevskii, A.
Thioye, M.
Zdrazil, M.
Farrell, J.
Kane, S.
author_sort Botchev, B.
collection CERN
description The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cryostat walls to the calorimeters cells (89 K) while maintaining the electrical and cryogenic integrity of the system. The feedthrough wiring and filters operate at a maximum high voltage of 2.5 kV without danger of degradation by corona discharges or radiation at the Large Hadron Collider.
id cern-1055349
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
record_format invenio
spelling cern-10553492023-03-14T18:21:37Zdoi:10.1088/1748-0221/2/10/T10002http://cds.cern.ch/record/1055349engBotchev, B.Finocchiaro, G.Hoffman, J.McCarthy, R.L.Rijssenbeek, M.Steffens, J.Talalaevskii, A.Thioye, M.Zdrazil, M.Farrell, J.Kane, S.The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimetersphysics.ins-detThe purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cryostat walls to the calorimeters cells (89 K) while maintaining the electrical and cryogenic integrity of the system. The feedthrough wiring and filters operate at a maximum high voltage of 2.5 kV without danger of degradation by corona discharges or radiation at the Large Hadron Collider.The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cryostat walls to the calorimeters cells (89 K) while maintaining the electrical and cryogenic integrity of the system. The feedthrough wiring and filters operate at a maximum high voltage of 2.5 kV without danger of degradation by corona discharges or radiation at the Large Hadron Collider.arXiv:0709.0744oai:cds.cern.ch:10553492007-09-07
spellingShingle physics.ins-det
Botchev, B.
Finocchiaro, G.
Hoffman, J.
McCarthy, R.L.
Rijssenbeek, M.
Steffens, J.
Talalaevskii, A.
Thioye, M.
Zdrazil, M.
Farrell, J.
Kane, S.
The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters
title The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters
title_full The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters
title_fullStr The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters
title_full_unstemmed The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters
title_short The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters
title_sort high voltage feedthroughs for the atlas liquid argon calorimeters
topic physics.ins-det
url https://dx.doi.org/10.1088/1748-0221/2/10/T10002
http://cds.cern.ch/record/1055349
work_keys_str_mv AT botchevb thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT finocchiarog thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT hoffmanj thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT mccarthyrl thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT rijssenbeekm thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT steffensj thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT talalaevskiia thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT thioyem thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT zdrazilm thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT farrellj thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT kanes thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT botchevb highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT finocchiarog highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT hoffmanj highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT mccarthyrl highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT rijssenbeekm highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT steffensj highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT talalaevskiia highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT thioyem highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT zdrazilm highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT farrellj highvoltagefeedthroughsfortheatlasliquidargoncalorimeters
AT kanes highvoltagefeedthroughsfortheatlasliquidargoncalorimeters