Cargando…
The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters
The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cry...
Autores principales: | , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/2/10/T10002 http://cds.cern.ch/record/1055349 |
_version_ | 1780913031514947584 |
---|---|
author | Botchev, B. Finocchiaro, G. Hoffman, J. McCarthy, R.L. Rijssenbeek, M. Steffens, J. Talalaevskii, A. Thioye, M. Zdrazil, M. Farrell, J. Kane, S. |
author_facet | Botchev, B. Finocchiaro, G. Hoffman, J. McCarthy, R.L. Rijssenbeek, M. Steffens, J. Talalaevskii, A. Thioye, M. Zdrazil, M. Farrell, J. Kane, S. |
author_sort | Botchev, B. |
collection | CERN |
description | The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cryostat walls to the calorimeters cells (89 K) while maintaining the electrical and cryogenic integrity of the system. The feedthrough wiring and filters operate at a maximum high voltage of 2.5 kV without danger of degradation by corona discharges or radiation at the Large Hadron Collider. |
id | cern-1055349 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10553492023-03-14T18:21:37Zdoi:10.1088/1748-0221/2/10/T10002http://cds.cern.ch/record/1055349engBotchev, B.Finocchiaro, G.Hoffman, J.McCarthy, R.L.Rijssenbeek, M.Steffens, J.Talalaevskii, A.Thioye, M.Zdrazil, M.Farrell, J.Kane, S.The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimetersphysics.ins-detThe purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cryostat walls to the calorimeters cells (89 K) while maintaining the electrical and cryogenic integrity of the system. The feedthrough wiring and filters operate at a maximum high voltage of 2.5 kV without danger of degradation by corona discharges or radiation at the Large Hadron Collider.The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires from a room-temperature environment (300 K) through the cryostat walls to the calorimeters cells (89 K) while maintaining the electrical and cryogenic integrity of the system. The feedthrough wiring and filters operate at a maximum high voltage of 2.5 kV without danger of degradation by corona discharges or radiation at the Large Hadron Collider.arXiv:0709.0744oai:cds.cern.ch:10553492007-09-07 |
spellingShingle | physics.ins-det Botchev, B. Finocchiaro, G. Hoffman, J. McCarthy, R.L. Rijssenbeek, M. Steffens, J. Talalaevskii, A. Thioye, M. Zdrazil, M. Farrell, J. Kane, S. The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters |
title | The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters |
title_full | The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters |
title_fullStr | The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters |
title_full_unstemmed | The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters |
title_short | The High Voltage Feedthroughs for the ATLAS Liquid Argon Calorimeters |
title_sort | high voltage feedthroughs for the atlas liquid argon calorimeters |
topic | physics.ins-det |
url | https://dx.doi.org/10.1088/1748-0221/2/10/T10002 http://cds.cern.ch/record/1055349 |
work_keys_str_mv | AT botchevb thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT finocchiarog thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT hoffmanj thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT mccarthyrl thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT rijssenbeekm thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT steffensj thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT talalaevskiia thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT thioyem thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT zdrazilm thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT farrellj thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT kanes thehighvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT botchevb highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT finocchiarog highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT hoffmanj highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT mccarthyrl highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT rijssenbeekm highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT steffensj highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT talalaevskiia highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT thioyem highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT zdrazilm highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT farrellj highvoltagefeedthroughsfortheatlasliquidargoncalorimeters AT kanes highvoltagefeedthroughsfortheatlasliquidargoncalorimeters |