Cargando…

Response Uniformity of the ATLAS Liquid Argon Electromagnetic Calorimeter

The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain th...

Descripción completa

Detalles Bibliográficos
Autores principales: Colas, J., Di Ciaccio, L., Gouanere, M., Lafaye, R., Laplace, S., Perrodo, P., Przysiezniak, H., Sauvage, G., Wingerter-Seez, I., Zitoun, R., Lanni, F., Lu, L., Ma, H., Rajagopalan, S., Takai, H., Belymam, A., Benchekroun, D., Hakimi, M., Hoummada, A., Gao, Y., Stroynowski, R., Aleksa, M., Carli, T., Fassnacht, P., Gianotti, F., Hervas, L., Lampl, W., Collot, Johann, Hostachy, J.Y., Ledroit-Guillon, F., Malek, Fairouz, Martin, P., Viret, S., Leltchouk, M., Parsons, J.A., Simion, S., Barreiro, F., Del Peso, J., Labarga, L., Oliver, C., Rodier, S., Djama, F., Hubaut, F., Monnier, E., Pralavorio, P., Serfon, C., Tisserant, S., Banfi, D., Carminati, L., Cavalli, D., Costa, G., Delmastro, M., Fanti, M., Mandelli, L., Mazzanti, M., Tartarelli, G.F., Kotov, K., Maslennikov, A., Pospelov, G., Tikhonov, Yu., Bourdarios, C., Fayard, L., Fournier, D., Iconomidou-Fayard, L., Parrour, G., Puzo, P., Rousseau, D., Serin, L., Zerwas, D., Dekhissi, B., Derkaoui, J., El Kharrim, A., Maaroufi, F., Cleland, W., Lacour, D., Laforge, B., Nikolic-Audit, I., Schwemling, Ph., Ghazlane, H., Cherkaoui El Moursli, R., Idrissi Fakhr-Eddine, A., Boonekamp, M., Kerschen, N., Mansoulie, B., Meyer, P., Schwindling, J., Lund-Jensen., B.
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2007.08.157
http://cds.cern.ch/record/1055693
Descripción
Sumario:The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.