Cargando…

Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

The CALICE Si-W electromagnetic calorimeter has been tested with electron beams (1 to 6 GeV) at DESY in May 2006, as well as electrons (6 to 45 GeV) and hadrons (6 to 80 GeV) at CERN in August and October 2006. Several millions of events have been taken at different incident angles and three beam im...

Descripción completa

Detalles Bibliográficos
Autores principales: Carloganu, C., Magnan, A.-M.
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:http://cds.cern.ch/record/1057356
_version_ 1780913096885272576
author Carloganu, C.
Magnan, A.-M.
author_facet Carloganu, C.
Magnan, A.-M.
author_sort Carloganu, C.
collection CERN
description The CALICE Si-W electromagnetic calorimeter has been tested with electron beams (1 to 6 GeV) at DESY in May 2006, as well as electrons (6 to 45 GeV) and hadrons (6 to 80 GeV) at CERN in August and October 2006. Several millions of events have been taken at different incident angles and three beam impact positions. The ECAL calibration is performed with muon beams and shows a good uniformity for nearly all channels. The large statistics available allows not only to characterise the ECAL physics performance, but also to identify subtle hardware effects.
id cern-1057356
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
record_format invenio
spelling cern-10573562019-09-30T06:29:59Zhttp://cds.cern.ch/record/1057356engCarloganu, C.Magnan, A.-M.Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006physics.ins-detThe CALICE Si-W electromagnetic calorimeter has been tested with electron beams (1 to 6 GeV) at DESY in May 2006, as well as electrons (6 to 45 GeV) and hadrons (6 to 80 GeV) at CERN in August and October 2006. Several millions of events have been taken at different incident angles and three beam impact positions. The ECAL calibration is performed with muon beams and shows a good uniformity for nearly all channels. The large statistics available allows not only to characterise the ECAL physics performance, but also to identify subtle hardware effects.arXiv:0709.2516LCWS-2007-CAL20-CAL21oai:cds.cern.ch:10573562007-09-18
spellingShingle physics.ins-det
Carloganu, C.
Magnan, A.-M.
Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006
title Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006
title_full Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006
title_fullStr Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006
title_full_unstemmed Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006
title_short Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006
title_sort calice si-w em calorimeter: preliminary results of the testbeams 2006
topic physics.ins-det
url http://cds.cern.ch/record/1057356
work_keys_str_mv AT carloganuc calicesiwemcalorimeterpreliminaryresultsofthetestbeams2006
AT magnanam calicesiwemcalorimeterpreliminaryresultsofthetestbeams2006