Cargando…
A prototype of very high-resolution small animal PET scanner using silicon pad detectors
Abstract A very high-resolution small animal positron emission tomograph (PET), which can achieve sub-millimeter spatial resolution, is being developed using silicon pad detectors. The prototype PET for a single slice instrument consists of two 1 mm thick silicon pad detectors, each containing a 32×...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2006.10.277 http://cds.cern.ch/record/1060555 |
_version_ | 1780913166278983680 |
---|---|
author | Park, S J Rogers, W L Huh, S Kagan, H Honscheid, K Burdette, D Chesi, Enrico Guido Lacasta, C Llosa, G Mikuz, M Studen, A Weilhammer, P Clinthorne, N H |
author_facet | Park, S J Rogers, W L Huh, S Kagan, H Honscheid, K Burdette, D Chesi, Enrico Guido Lacasta, C Llosa, G Mikuz, M Studen, A Weilhammer, P Clinthorne, N H |
author_sort | Park, S J |
collection | CERN |
description | Abstract A very high-resolution small animal positron emission tomograph (PET), which can achieve sub-millimeter spatial resolution, is being developed using silicon pad detectors. The prototype PET for a single slice instrument consists of two 1 mm thick silicon pad detectors, each containing a 32×16 array of 1.4×1.4 mm pads readout with four VATAGP3 chips which have 128 channels low-noise self-triggering ASIC in each chip, coincidence units, a source turntable and tungsten slice collimator. The silicon detectors were located edgewise on opposite sides of a 4 cm field-of-view to maximize efficiency. Energy resolution is dominated by electronic noise, which is 0.98% (1.38 keV) FWHM at 140.5 keV. Coincidence timing resolution is 82.1 ns FWHM and coincidence efficiency was measured to be 1.04×10−3% from two silicon detectors with annihilation photons of 18F source. Image data were acquired and reconstructed using conventional 2-D filtered-back projection (FBP) and a maximum likelihood expectation maximization (ML-EM) method. Image resolution of approximately 1.45 mm FWHM is obtained from 1-D profile of 1.1 mm diameter 18F line source image. Even better resolution can be obtained with smaller detector element sizes. While many challenges remain in scaling up the instrument to useful efficiency including densely packed detectors and significantly improved timing resolution, performance of the test setup in terms of easily achieving sub-millimeter resolution is compelling. |
id | cern-1060555 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10605552019-09-30T06:29:59Zdoi:10.1016/j.nima.2006.10.277http://cds.cern.ch/record/1060555engPark, S JRogers, W LHuh, SKagan, HHonscheid, KBurdette, DChesi, Enrico GuidoLacasta, CLlosa, GMikuz, MStuden, AWeilhammer, PClinthorne, N HA prototype of very high-resolution small animal PET scanner using silicon pad detectorsDetectors and Experimental TechniquesAbstract A very high-resolution small animal positron emission tomograph (PET), which can achieve sub-millimeter spatial resolution, is being developed using silicon pad detectors. The prototype PET for a single slice instrument consists of two 1 mm thick silicon pad detectors, each containing a 32×16 array of 1.4×1.4 mm pads readout with four VATAGP3 chips which have 128 channels low-noise self-triggering ASIC in each chip, coincidence units, a source turntable and tungsten slice collimator. The silicon detectors were located edgewise on opposite sides of a 4 cm field-of-view to maximize efficiency. Energy resolution is dominated by electronic noise, which is 0.98% (1.38 keV) FWHM at 140.5 keV. Coincidence timing resolution is 82.1 ns FWHM and coincidence efficiency was measured to be 1.04×10−3% from two silicon detectors with annihilation photons of 18F source. Image data were acquired and reconstructed using conventional 2-D filtered-back projection (FBP) and a maximum likelihood expectation maximization (ML-EM) method. Image resolution of approximately 1.45 mm FWHM is obtained from 1-D profile of 1.1 mm diameter 18F line source image. Even better resolution can be obtained with smaller detector element sizes. While many challenges remain in scaling up the instrument to useful efficiency including densely packed detectors and significantly improved timing resolution, performance of the test setup in terms of easily achieving sub-millimeter resolution is compelling.oai:cds.cern.ch:10605552007 |
spellingShingle | Detectors and Experimental Techniques Park, S J Rogers, W L Huh, S Kagan, H Honscheid, K Burdette, D Chesi, Enrico Guido Lacasta, C Llosa, G Mikuz, M Studen, A Weilhammer, P Clinthorne, N H A prototype of very high-resolution small animal PET scanner using silicon pad detectors |
title | A prototype of very high-resolution small animal PET scanner using silicon pad detectors |
title_full | A prototype of very high-resolution small animal PET scanner using silicon pad detectors |
title_fullStr | A prototype of very high-resolution small animal PET scanner using silicon pad detectors |
title_full_unstemmed | A prototype of very high-resolution small animal PET scanner using silicon pad detectors |
title_short | A prototype of very high-resolution small animal PET scanner using silicon pad detectors |
title_sort | prototype of very high-resolution small animal pet scanner using silicon pad detectors |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2006.10.277 http://cds.cern.ch/record/1060555 |
work_keys_str_mv | AT parksj aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT rogerswl aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT huhs aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT kaganh aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT honscheidk aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT burdetted aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT chesienricoguido aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT lacastac aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT llosag aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT mikuzm aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT studena aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT weilhammerp aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT clinthornenh aprototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT parksj prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT rogerswl prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT huhs prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT kaganh prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT honscheidk prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT burdetted prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT chesienricoguido prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT lacastac prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT llosag prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT mikuzm prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT studena prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT weilhammerp prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors AT clinthornenh prototypeofveryhighresolutionsmallanimalpetscannerusingsiliconpaddetectors |