CMS electromagnetic calorimeter performance and test beam results
Energy resolution of the CMS crystal electromagnetic calorimeter has been measured with an electron test beam using a fully equipped barrel supermodule. Both intrinsic energy resolution and energy resolution for electrons with quasi-uniform impact on the crystal surface are measured. The amplitude o...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2006.10.234 http://cds.cern.ch/record/1062703 |
_version_ | 1780913209064030208 |
---|---|
author | Brunelière, R |
author_facet | Brunelière, R |
author_sort | Brunelière, R |
collection | CERN |
description | Energy resolution of the CMS crystal electromagnetic calorimeter has been measured with an electron test beam using a fully equipped barrel supermodule. Both intrinsic energy resolution and energy resolution for electrons with quasi-uniform impact on the crystal surface are measured. The amplitude of the signal collected from crystals is reconstructed by a digital filtering technique and corrections for the position dependent response are applied in the case of quasi-uniform impact. The resolution measured for the supermodule is fully compatible with design expectations. |
id | cern-1062703 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10627032019-09-30T06:29:59Zdoi:10.1016/j.nima.2006.10.234http://cds.cern.ch/record/1062703engBrunelière, RCMS electromagnetic calorimeter performance and test beam resultsDetectors and Experimental TechniquesEnergy resolution of the CMS crystal electromagnetic calorimeter has been measured with an electron test beam using a fully equipped barrel supermodule. Both intrinsic energy resolution and energy resolution for electrons with quasi-uniform impact on the crystal surface are measured. The amplitude of the signal collected from crystals is reconstructed by a digital filtering technique and corrections for the position dependent response are applied in the case of quasi-uniform impact. The resolution measured for the supermodule is fully compatible with design expectations.oai:cds.cern.ch:10627032007 |
spellingShingle | Detectors and Experimental Techniques Brunelière, R CMS electromagnetic calorimeter performance and test beam results |
title | CMS electromagnetic calorimeter performance and test beam results |
title_full | CMS electromagnetic calorimeter performance and test beam results |
title_fullStr | CMS electromagnetic calorimeter performance and test beam results |
title_full_unstemmed | CMS electromagnetic calorimeter performance and test beam results |
title_short | CMS electromagnetic calorimeter performance and test beam results |
title_sort | cms electromagnetic calorimeter performance and test beam results |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2006.10.234 http://cds.cern.ch/record/1062703 |
work_keys_str_mv | AT brunelierer cmselectromagneticcalorimeterperformanceandtestbeamresults |