Cargando…
A Time-Based Front End Readout System for PET & CT
In the framework of the European FP6's BioCare project, we develop a novel, time-based, photo-detector readout technique to increase sensitivity and timing precision for molecular imaging in PET and CT. The project aims to employ Avalanche Photo Diode (APD) arrays with state of the art, high sp...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1063360 |
_version_ | 1780913223502921728 |
---|---|
author | Meyer, T C Powolny, F Anghinolfi, F Auffray, E Dosanjh, M Hillemanns, H Hoffmann, H -F Jarron, P Kaplon, J Kronberger, M Lecoq, P Moraes, D Trummer, J |
author_facet | Meyer, T C Powolny, F Anghinolfi, F Auffray, E Dosanjh, M Hillemanns, H Hoffmann, H -F Jarron, P Kaplon, J Kronberger, M Lecoq, P Moraes, D Trummer, J |
author_sort | Meyer, T C |
collection | CERN |
description | In the framework of the European FP6's BioCare project, we develop a novel, time-based, photo-detector readout technique to increase sensitivity and timing precision for molecular imaging in PET and CT. The project aims to employ Avalanche Photo Diode (APD) arrays with state of the art, high speed, front end amplifiers and discrimination circuits developed for the Large Hadron Collider (LHC) physics program at CERN, suitable to detect and process photons in a combined one-unit PET/CT detection head. In the so-called time-based approach our efforts focus on the system's timing performance with sub-nanosecond time-jitter and -walk, and yet also provide information on photon energy without resorting to analog to digital conversion. The bandwidth of the electronic circuitry is compatible with the scintillator's intrinsic light response (e.g. les40ns in LSO) and hence allows high rate CT operation in single-photon counting mode. Based on commercial LSO crystals and Hamamatsu S8550 APD arrays, we show the system performance in terms of timing- and energy resolution as well as its rate behavior (SPICE, simulating a high intensity X-ray beam). If proven viable, this technique may lead to the construction of a compact, radiation tolerant, and cost effective PET/CT detection head in one unit. |
id | cern-1063360 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10633602019-09-30T06:29:59Zhttp://cds.cern.ch/record/1063360engMeyer, T CPowolny, FAnghinolfi, FAuffray, EDosanjh, MHillemanns, HHoffmann, H -FJarron, PKaplon, JKronberger, MLecoq, PMoraes, DTrummer, JA Time-Based Front End Readout System for PET & CTDetectors and Experimental TechniquesIn the framework of the European FP6's BioCare project, we develop a novel, time-based, photo-detector readout technique to increase sensitivity and timing precision for molecular imaging in PET and CT. The project aims to employ Avalanche Photo Diode (APD) arrays with state of the art, high speed, front end amplifiers and discrimination circuits developed for the Large Hadron Collider (LHC) physics program at CERN, suitable to detect and process photons in a combined one-unit PET/CT detection head. In the so-called time-based approach our efforts focus on the system's timing performance with sub-nanosecond time-jitter and -walk, and yet also provide information on photon energy without resorting to analog to digital conversion. The bandwidth of the electronic circuitry is compatible with the scintillator's intrinsic light response (e.g. les40ns in LSO) and hence allows high rate CT operation in single-photon counting mode. Based on commercial LSO crystals and Hamamatsu S8550 APD arrays, we show the system performance in terms of timing- and energy resolution as well as its rate behavior (SPICE, simulating a high intensity X-ray beam). If proven viable, this technique may lead to the construction of a compact, radiation tolerant, and cost effective PET/CT detection head in one unit.oai:cds.cern.ch:10633602007 |
spellingShingle | Detectors and Experimental Techniques Meyer, T C Powolny, F Anghinolfi, F Auffray, E Dosanjh, M Hillemanns, H Hoffmann, H -F Jarron, P Kaplon, J Kronberger, M Lecoq, P Moraes, D Trummer, J A Time-Based Front End Readout System for PET & CT |
title | A Time-Based Front End Readout System for PET & CT |
title_full | A Time-Based Front End Readout System for PET & CT |
title_fullStr | A Time-Based Front End Readout System for PET & CT |
title_full_unstemmed | A Time-Based Front End Readout System for PET & CT |
title_short | A Time-Based Front End Readout System for PET & CT |
title_sort | time-based front end readout system for pet & ct |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1063360 |
work_keys_str_mv | AT meyertc atimebasedfrontendreadoutsystemforpetct AT powolnyf atimebasedfrontendreadoutsystemforpetct AT anghinolfif atimebasedfrontendreadoutsystemforpetct AT auffraye atimebasedfrontendreadoutsystemforpetct AT dosanjhm atimebasedfrontendreadoutsystemforpetct AT hillemannsh atimebasedfrontendreadoutsystemforpetct AT hoffmannhf atimebasedfrontendreadoutsystemforpetct AT jarronp atimebasedfrontendreadoutsystemforpetct AT kaplonj atimebasedfrontendreadoutsystemforpetct AT kronbergerm atimebasedfrontendreadoutsystemforpetct AT lecoqp atimebasedfrontendreadoutsystemforpetct AT moraesd atimebasedfrontendreadoutsystemforpetct AT trummerj atimebasedfrontendreadoutsystemforpetct AT meyertc timebasedfrontendreadoutsystemforpetct AT powolnyf timebasedfrontendreadoutsystemforpetct AT anghinolfif timebasedfrontendreadoutsystemforpetct AT auffraye timebasedfrontendreadoutsystemforpetct AT dosanjhm timebasedfrontendreadoutsystemforpetct AT hillemannsh timebasedfrontendreadoutsystemforpetct AT hoffmannhf timebasedfrontendreadoutsystemforpetct AT jarronp timebasedfrontendreadoutsystemforpetct AT kaplonj timebasedfrontendreadoutsystemforpetct AT kronbergerm timebasedfrontendreadoutsystemforpetct AT lecoqp timebasedfrontendreadoutsystemforpetct AT moraesd timebasedfrontendreadoutsystemforpetct AT trummerj timebasedfrontendreadoutsystemforpetct |