Cargando…

Using Double Tagging to measure the Performance of the Same Side Kaon Tagger in Data

This note describes a method for the measurement of the wrong-tag fraction of the Same Side Kaon tagger, $\omega_{ss}$ in data using the Double Tagging procedure. The importance of such a measurement is explained and the method of Double Tagging described. This measurement was carried out using samp...

Descripción completa

Detalles Bibliográficos
Autores principales: Awunor, O, Egede, U
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:http://cds.cern.ch/record/1064485
_version_ 1780913245818716160
author Awunor, O
Egede, U
author_facet Awunor, O
Egede, U
author_sort Awunor, O
collection CERN
description This note describes a method for the measurement of the wrong-tag fraction of the Same Side Kaon tagger, $\omega_{ss}$ in data using the Double Tagging procedure. The importance of such a measurement is explained and the method of Double Tagging described. This measurement was carried out using samples from reconstructed $Bs -> Ds\pi$ and $Bs -> Ds\mu\nu$ decays. The impact of background in both decay channels on the measurement of $\omega_{ss}$ was also studied. A general way of handling tagger correlations is presented. Finally, the Double Tagging measurement and the correlation investigation are performed on the present Monte Carlo data and the results presented. Results show that with 2fb-1 of data, the Double Tagging procedure can be used to measure the SS Kaon wrong-tag fraction to a statistical accuracy of 3.6% and 1.2% for the $Bs -> Ds\pi$ and $Bs -> Ds\mu\nu$ channels respectively.
id cern-1064485
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
record_format invenio
spelling cern-10644852019-09-30T06:29:59Zhttp://cds.cern.ch/record/1064485engAwunor, OEgede, UUsing Double Tagging to measure the Performance of the Same Side Kaon Tagger in DataDetectors and Experimental TechniquesThis note describes a method for the measurement of the wrong-tag fraction of the Same Side Kaon tagger, $\omega_{ss}$ in data using the Double Tagging procedure. The importance of such a measurement is explained and the method of Double Tagging described. This measurement was carried out using samples from reconstructed $Bs -> Ds\pi$ and $Bs -> Ds\mu\nu$ decays. The impact of background in both decay channels on the measurement of $\omega_{ss}$ was also studied. A general way of handling tagger correlations is presented. Finally, the Double Tagging measurement and the correlation investigation are performed on the present Monte Carlo data and the results presented. Results show that with 2fb-1 of data, the Double Tagging procedure can be used to measure the SS Kaon wrong-tag fraction to a statistical accuracy of 3.6% and 1.2% for the $Bs -> Ds\pi$ and $Bs -> Ds\mu\nu$ channels respectively.LHCb-2007-127CERN-LHCb-2007-127oai:cds.cern.ch:10644852007-10-24
spellingShingle Detectors and Experimental Techniques
Awunor, O
Egede, U
Using Double Tagging to measure the Performance of the Same Side Kaon Tagger in Data
title Using Double Tagging to measure the Performance of the Same Side Kaon Tagger in Data
title_full Using Double Tagging to measure the Performance of the Same Side Kaon Tagger in Data
title_fullStr Using Double Tagging to measure the Performance of the Same Side Kaon Tagger in Data
title_full_unstemmed Using Double Tagging to measure the Performance of the Same Side Kaon Tagger in Data
title_short Using Double Tagging to measure the Performance of the Same Side Kaon Tagger in Data
title_sort using double tagging to measure the performance of the same side kaon tagger in data
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1064485
work_keys_str_mv AT awunoro usingdoubletaggingtomeasuretheperformanceofthesamesidekaontaggerindata
AT egedeu usingdoubletaggingtomeasuretheperformanceofthesamesidekaontaggerindata