Cargando…
VFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors
The architecture, key design parameters and results for a highly integrated front-end readout system fabricated as a single ASIC are presented. The chip (VFAT2) comprises complex analog and digital functions traditionally designed as separate components. VFAT2 contains very low noise 128 channel fro...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-2007-007.292 http://cds.cern.ch/record/1069906 |
_version_ | 1780913358362378240 |
---|---|
author | Aspell, P Anelli, G Chalmet, P Kaplon, J Kloukinas, K Mugnier, H Snoeys, W |
author_facet | Aspell, P Anelli, G Chalmet, P Kaplon, J Kloukinas, K Mugnier, H Snoeys, W |
author_sort | Aspell, P |
collection | CERN |
description | The architecture, key design parameters and results for a highly integrated front-end readout system fabricated as a single ASIC are presented. The chip (VFAT2) comprises complex analog and digital functions traditionally designed as separate components. VFAT2 contains very low noise 128 channel front-end amplification with programmable internal calibration, intelligent “fast OR” trigger building outputs, digital data tagging and storage, data formatting and data packet transmission with error protection. VFAT2 is designed to work in the demanding radiation environments posed by modern H.E.P. experiments and in particular the TOTEM experiment of the LHC. Measured results are presented demonstrating full functionality and excellent analog performance despite intensive digital activity on the same piece of silicon. |
id | cern-1069906 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
publisher | CERN |
record_format | invenio |
spelling | cern-10699062019-09-30T06:29:59Zdoi:10.5170/CERN-2007-007.292http://cds.cern.ch/record/1069906engAspell, PAnelli, GChalmet, PKaplon, JKloukinas, KMugnier, HSnoeys, WVFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectorsDetectors and Experimental TechniquesThe architecture, key design parameters and results for a highly integrated front-end readout system fabricated as a single ASIC are presented. The chip (VFAT2) comprises complex analog and digital functions traditionally designed as separate components. VFAT2 contains very low noise 128 channel front-end amplification with programmable internal calibration, intelligent “fast OR” trigger building outputs, digital data tagging and storage, data formatting and data packet transmission with error protection. VFAT2 is designed to work in the demanding radiation environments posed by modern H.E.P. experiments and in particular the TOTEM experiment of the LHC. Measured results are presented demonstrating full functionality and excellent analog performance despite intensive digital activity on the same piece of silicon.CERNoai:cds.cern.ch:10699062007 |
spellingShingle | Detectors and Experimental Techniques Aspell, P Anelli, G Chalmet, P Kaplon, J Kloukinas, K Mugnier, H Snoeys, W VFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors |
title | VFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors |
title_full | VFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors |
title_fullStr | VFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors |
title_full_unstemmed | VFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors |
title_short | VFAT2: A front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors |
title_sort | vfat2: a front-end system on chip providing fast trigger information, digitized data storage and formatting for the charge sensitive readout of multi-channel silicon and gas particle detectors |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.5170/CERN-2007-007.292 http://cds.cern.ch/record/1069906 |
work_keys_str_mv | AT aspellp vfat2afrontendsystemonchipprovidingfasttriggerinformationdigitizeddatastorageandformattingforthechargesensitivereadoutofmultichannelsiliconandgasparticledetectors AT anellig vfat2afrontendsystemonchipprovidingfasttriggerinformationdigitizeddatastorageandformattingforthechargesensitivereadoutofmultichannelsiliconandgasparticledetectors AT chalmetp vfat2afrontendsystemonchipprovidingfasttriggerinformationdigitizeddatastorageandformattingforthechargesensitivereadoutofmultichannelsiliconandgasparticledetectors AT kaplonj vfat2afrontendsystemonchipprovidingfasttriggerinformationdigitizeddatastorageandformattingforthechargesensitivereadoutofmultichannelsiliconandgasparticledetectors AT kloukinask vfat2afrontendsystemonchipprovidingfasttriggerinformationdigitizeddatastorageandformattingforthechargesensitivereadoutofmultichannelsiliconandgasparticledetectors AT mugnierh vfat2afrontendsystemonchipprovidingfasttriggerinformationdigitizeddatastorageandformattingforthechargesensitivereadoutofmultichannelsiliconandgasparticledetectors AT snoeysw vfat2afrontendsystemonchipprovidingfasttriggerinformationdigitizeddatastorageandformattingforthechargesensitivereadoutofmultichannelsiliconandgasparticledetectors |