Cargando…

The Data Quality Monitoring for the CMS Electromagnetic Calorimeter

The detector performance of the CMS electromagnetic calorimeter is monitored using applications based on the CMS Data Quality Monitoring (DQM) framework and running on the High-Level Trigger Farm as well as on local DAQ systems. The monitorable quantities are organized into hierarchical structures b...

Descripción completa

Detalles Bibliográficos
Autores principales: Della Ricca, Giuseppe, Di Marco, Emanuele, Franzoni, Giovanni, Gobbo, Benigno
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1742-6596/119/2/022018
http://cds.cern.ch/record/1073701
Descripción
Sumario:The detector performance of the CMS electromagnetic calorimeter is monitored using applications based on the CMS Data Quality Monitoring (DQM) framework and running on the High-Level Trigger Farm as well as on local DAQ systems. The monitorable quantities are organized into hierarchical structures based on the physics content. The information produced is accessible by client applications according to their subscription requests. The client applications process the received quantities, according to pre-defined analyses, making the results immediately available, while also storing the results in a database, and in the form of static web pages, for subsequent studies. We describe here the functionalities of the CMS ECAL DQM applications and report about their use in real environments.