Cargando…

The CMS-HF Forward Calorimeter Commissioning

The CMS HF Calorimeter was the first detector to be lowered into the cavern at UX5. It was placed in the garage position during the lowering of the rest of the big CMS pieces. The commissioning of the hardware parts is continuing. Especially, integrating the HF and completing the monitoring systems,...

Descripción completa

Detalles Bibliográficos
Autor principal: Gülmez, E
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:https://dx.doi.org/10.1142/9789812819093_0057
http://cds.cern.ch/record/1073705
_version_ 1780913430960537600
author Gülmez, E
author_facet Gülmez, E
author_sort Gülmez, E
collection CERN
description The CMS HF Calorimeter was the first detector to be lowered into the cavern at UX5. It was placed in the garage position during the lowering of the rest of the big CMS pieces. The commissioning of the hardware parts is continuing. Especially, integrating the HF and completing the monitoring systems, such as, online laser, LED and radioactive source monitoring. Also a special monitor system for the radiation damage (raddam) of the quartz fibers is being implemented. Calibration measurements of the calorimeter had started already even before the lowering. Progress in the calibration work and current plans for the HF calorimeter during the low luminosity run will be summarized.
id cern-1073705
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
record_format invenio
spelling cern-10737052019-09-30T06:29:59Zdoi:10.1142/9789812819093_0057http://cds.cern.ch/record/1073705engGülmez, EThe CMS-HF Forward Calorimeter CommissioningDetectors and Experimental TechniquesThe CMS HF Calorimeter was the first detector to be lowered into the cavern at UX5. It was placed in the garage position during the lowering of the rest of the big CMS pieces. The commissioning of the hardware parts is continuing. Especially, integrating the HF and completing the monitoring systems, such as, online laser, LED and radioactive source monitoring. Also a special monitor system for the radiation damage (raddam) of the quartz fibers is being implemented. Calibration measurements of the calorimeter had started already even before the lowering. Progress in the calibration work and current plans for the HF calorimeter during the low luminosity run will be summarized.CMS-CR-2007-071oai:cds.cern.ch:10737052007-11-12
spellingShingle Detectors and Experimental Techniques
Gülmez, E
The CMS-HF Forward Calorimeter Commissioning
title The CMS-HF Forward Calorimeter Commissioning
title_full The CMS-HF Forward Calorimeter Commissioning
title_fullStr The CMS-HF Forward Calorimeter Commissioning
title_full_unstemmed The CMS-HF Forward Calorimeter Commissioning
title_short The CMS-HF Forward Calorimeter Commissioning
title_sort cms-hf forward calorimeter commissioning
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1142/9789812819093_0057
http://cds.cern.ch/record/1073705
work_keys_str_mv AT gulmeze thecmshfforwardcalorimetercommissioning
AT gulmeze cmshfforwardcalorimetercommissioning