Signal reconstruction in the EM end-cap calorimeter and check with cosmic data in the region 0< eta <3.2

In 2007, the electromagnetic end-cap calorimeter joined the ATLAS commissioning effort. Since then, calibration and cosmic muon runs are taken regularly, allowing to set-up, debug and test in situ the signal reconstruction. These are the first data in the 1.4< eta <3.2 region since 2001-2002 t...

Descripción completa

Detalles Bibliográficos
Autores principales: Gabaldon, C, Kuna, M, Hubaut, F, Pralavorio, P, Del Peso, J
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:http://cds.cern.ch/record/1090053
Descripción
Sumario:In 2007, the electromagnetic end-cap calorimeter joined the ATLAS commissioning effort. Since then, calibration and cosmic muon runs are taken regularly, allowing to set-up, debug and test in situ the signal reconstruction. These are the first data in the 1.4< eta <3.2 region since 2001-2002 test beam period. The few \% of cosmic events with catastrophic high energy deposits (typically E>500 MeV) have been used to perform a systematic and quantitative comparison between data and predicted physics pulse shapes in a coherent way over the entire calorimeter coverage, 0< eta <3.2. This represents the first attempt to unify barrel and end-cap in situ data in a common analysis. Results are similar in the barrel and the end-cap, only slightly worse for the latter as expected from its more complex geometry. This is the first proof of the quality of an ATLAS-like signal reconstruction in the end-caps, despite its challenging aspect, and gives confidence that the energy reconstruction is in good control over the complete electromagnetic calorimeter coverage 0< eta <3.2.