Distribution of the Timing, Trigger and Control Signals in the Endcap Cathode Strip Chamber System at CMS
This paper presents the implementation of the Timing, Trigger and Control (TTC) signal distribution tree in the Cathode Strip Chamber (CSC) sub-detector of the CMS Experiment at CERN. The key electronic component, the Clock and Control Board (CCB) is described in detail, as well as the transmission...