Cargando…

Development and first tests of GEM-like detectors with resistive electrodes

We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers or completely made of resistive materials. These detectors can operate stably at gains close to 105. The resistive layers limit the energy of discharges appearing at higher gains thus m...

Descripción completa

Detalles Bibliográficos
Autores principales: Peskov, Vladimir, Baibussinov, B, Centro, Sandro, Di Mauro, A, Lund-Jensen, B, Martinengo, P, Nappi, E, Oliveira, R, Pietropaolo, F, Picchi, P, Periale, L, Rodionov, I, Ventura, Sandro
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.2007.905160
http://cds.cern.ch/record/1096127
_version_ 1780913891353559040
author Peskov, Vladimir
Baibussinov, B
Centro, Sandro
Di Mauro, A
Lund-Jensen, B
Martinengo, P
Nappi, E
Oliveira, R
Pietropaolo, F
Picchi, P
Periale, L
Rodionov, I
Ventura, Sandro
author_facet Peskov, Vladimir
Baibussinov, B
Centro, Sandro
Di Mauro, A
Lund-Jensen, B
Martinengo, P
Nappi, E
Oliveira, R
Pietropaolo, F
Picchi, P
Periale, L
Rodionov, I
Ventura, Sandro
author_sort Peskov, Vladimir
collection CERN
description We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers or completely made of resistive materials. These detectors can operate stably at gains close to 105. The resistive layers limit the energy of discharges appearing at higher gains thus making the detectors very robust. We demonstrated that the cathodes of some of these detectors could be coated by CsI or SbCs layers to enhance the detection efficiency for the UV and visible photons. We also discovered that such detectors can operate stably in the cascade mode and high overall gains ($~10^{6}$) are reachable. Applications in several areas, for example in RICH or in noble liquid TPCs are therefore possible. The first results from the detection of UV photons at room and cryogenic temperatures will be given.
id cern-1096127
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
record_format invenio
spelling cern-10961272019-09-30T06:29:59Zdoi:10.1109/TNS.2007.905160http://cds.cern.ch/record/1096127engPeskov, VladimirBaibussinov, BCentro, SandroDi Mauro, ALund-Jensen, BMartinengo, PNappi, EOliveira, RPietropaolo, FPicchi, PPeriale, LRodionov, IVentura, SandroDevelopment and first tests of GEM-like detectors with resistive electrodesDetectors and Experimental TechniquesWe have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers or completely made of resistive materials. These detectors can operate stably at gains close to 105. The resistive layers limit the energy of discharges appearing at higher gains thus making the detectors very robust. We demonstrated that the cathodes of some of these detectors could be coated by CsI or SbCs layers to enhance the detection efficiency for the UV and visible photons. We also discovered that such detectors can operate stably in the cascade mode and high overall gains ($~10^{6}$) are reachable. Applications in several areas, for example in RICH or in noble liquid TPCs are therefore possible. The first results from the detection of UV photons at room and cryogenic temperatures will be given.oai:cds.cern.ch:10961272007
spellingShingle Detectors and Experimental Techniques
Peskov, Vladimir
Baibussinov, B
Centro, Sandro
Di Mauro, A
Lund-Jensen, B
Martinengo, P
Nappi, E
Oliveira, R
Pietropaolo, F
Picchi, P
Periale, L
Rodionov, I
Ventura, Sandro
Development and first tests of GEM-like detectors with resistive electrodes
title Development and first tests of GEM-like detectors with resistive electrodes
title_full Development and first tests of GEM-like detectors with resistive electrodes
title_fullStr Development and first tests of GEM-like detectors with resistive electrodes
title_full_unstemmed Development and first tests of GEM-like detectors with resistive electrodes
title_short Development and first tests of GEM-like detectors with resistive electrodes
title_sort development and first tests of gem-like detectors with resistive electrodes
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TNS.2007.905160
http://cds.cern.ch/record/1096127
work_keys_str_mv AT peskovvladimir developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT baibussinovb developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT centrosandro developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT dimauroa developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT lundjensenb developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT martinengop developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT nappie developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT oliveirar developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT pietropaolof developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT picchip developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT perialel developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT rodionovi developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes
AT venturasandro developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes