Cargando…
Development and first tests of GEM-like detectors with resistive electrodes
We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers or completely made of resistive materials. These detectors can operate stably at gains close to 105. The resistive layers limit the energy of discharges appearing at higher gains thus m...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2007
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TNS.2007.905160 http://cds.cern.ch/record/1096127 |
_version_ | 1780913891353559040 |
---|---|
author | Peskov, Vladimir Baibussinov, B Centro, Sandro Di Mauro, A Lund-Jensen, B Martinengo, P Nappi, E Oliveira, R Pietropaolo, F Picchi, P Periale, L Rodionov, I Ventura, Sandro |
author_facet | Peskov, Vladimir Baibussinov, B Centro, Sandro Di Mauro, A Lund-Jensen, B Martinengo, P Nappi, E Oliveira, R Pietropaolo, F Picchi, P Periale, L Rodionov, I Ventura, Sandro |
author_sort | Peskov, Vladimir |
collection | CERN |
description | We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers or completely made of resistive materials. These detectors can operate stably at gains close to 105. The resistive layers limit the energy of discharges appearing at higher gains thus making the detectors very robust. We demonstrated that the cathodes of some of these detectors could be coated by CsI or SbCs layers to enhance the detection efficiency for the UV and visible photons. We also discovered that such detectors can operate stably in the cascade mode and high overall gains ($~10^{6}$) are reachable. Applications in several areas, for example in RICH or in noble liquid TPCs are therefore possible. The first results from the detection of UV photons at room and cryogenic temperatures will be given. |
id | cern-1096127 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
record_format | invenio |
spelling | cern-10961272019-09-30T06:29:59Zdoi:10.1109/TNS.2007.905160http://cds.cern.ch/record/1096127engPeskov, VladimirBaibussinov, BCentro, SandroDi Mauro, ALund-Jensen, BMartinengo, PNappi, EOliveira, RPietropaolo, FPicchi, PPeriale, LRodionov, IVentura, SandroDevelopment and first tests of GEM-like detectors with resistive electrodesDetectors and Experimental TechniquesWe have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers or completely made of resistive materials. These detectors can operate stably at gains close to 105. The resistive layers limit the energy of discharges appearing at higher gains thus making the detectors very robust. We demonstrated that the cathodes of some of these detectors could be coated by CsI or SbCs layers to enhance the detection efficiency for the UV and visible photons. We also discovered that such detectors can operate stably in the cascade mode and high overall gains ($~10^{6}$) are reachable. Applications in several areas, for example in RICH or in noble liquid TPCs are therefore possible. The first results from the detection of UV photons at room and cryogenic temperatures will be given.oai:cds.cern.ch:10961272007 |
spellingShingle | Detectors and Experimental Techniques Peskov, Vladimir Baibussinov, B Centro, Sandro Di Mauro, A Lund-Jensen, B Martinengo, P Nappi, E Oliveira, R Pietropaolo, F Picchi, P Periale, L Rodionov, I Ventura, Sandro Development and first tests of GEM-like detectors with resistive electrodes |
title | Development and first tests of GEM-like detectors with resistive electrodes |
title_full | Development and first tests of GEM-like detectors with resistive electrodes |
title_fullStr | Development and first tests of GEM-like detectors with resistive electrodes |
title_full_unstemmed | Development and first tests of GEM-like detectors with resistive electrodes |
title_short | Development and first tests of GEM-like detectors with resistive electrodes |
title_sort | development and first tests of gem-like detectors with resistive electrodes |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/TNS.2007.905160 http://cds.cern.ch/record/1096127 |
work_keys_str_mv | AT peskovvladimir developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT baibussinovb developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT centrosandro developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT dimauroa developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT lundjensenb developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT martinengop developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT nappie developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT oliveirar developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT pietropaolof developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT picchip developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT perialel developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT rodionovi developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes AT venturasandro developmentandfirsttestsofgemlikedetectorswithresistiveelectrodes |