Cargando…
RF-Based Electron Beam Timing Measurement with Sub-10FS Resolution
Time of flight measurements of a relativistic electron beam have been performed and have demonstrated a resolution below 10 fs. The electronics consisted of a heterodyne receiver incorporating an array of analogue phase detectors in order to reduce noise. The performance of the system makes it suita...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1096209 |
_version_ | 1780913905589026816 |
---|---|
author | Andersson, A Sladen, J P H |
author_facet | Andersson, A Sladen, J P H |
author_sort | Andersson, A |
collection | CERN |
description | Time of flight measurements of a relativistic electron beam have been performed and have demonstrated a resolution below 10 fs. The electronics consisted of a heterodyne receiver incorporating an array of analogue phase detectors in order to reduce noise. The performance of the system makes it suitable for the challenging requirements of intra-pulse train timing measurements in a future linear collider. |
id | cern-1096209 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
record_format | invenio |
spelling | cern-10962092023-07-20T15:04:14Zhttp://cds.cern.ch/record/1096209engAndersson, ASladen, J P HRF-Based Electron Beam Timing Measurement with Sub-10FS ResolutionAccelerators and Storage RingsTime of flight measurements of a relativistic electron beam have been performed and have demonstrated a resolution below 10 fs. The electronics consisted of a heterodyne receiver incorporating an array of analogue phase detectors in order to reduce noise. The performance of the system makes it suitable for the challenging requirements of intra-pulse train timing measurements in a future linear collider.CERN-AB-2008-003CLIC-Note-734EUROTEV-Report-2008-015oai:cds.cern.ch:10962092008 |
spellingShingle | Accelerators and Storage Rings Andersson, A Sladen, J P H RF-Based Electron Beam Timing Measurement with Sub-10FS Resolution |
title | RF-Based Electron Beam Timing Measurement with Sub-10FS Resolution |
title_full | RF-Based Electron Beam Timing Measurement with Sub-10FS Resolution |
title_fullStr | RF-Based Electron Beam Timing Measurement with Sub-10FS Resolution |
title_full_unstemmed | RF-Based Electron Beam Timing Measurement with Sub-10FS Resolution |
title_short | RF-Based Electron Beam Timing Measurement with Sub-10FS Resolution |
title_sort | rf-based electron beam timing measurement with sub-10fs resolution |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1096209 |
work_keys_str_mv | AT anderssona rfbasedelectronbeamtimingmeasurementwithsub10fsresolution AT sladenjph rfbasedelectronbeamtimingmeasurementwithsub10fsresolution |