Inter-calibration of the CMS Barrel Electromagnetic Calorimeter Using $\pi^0 \rightarrow \gamma\gamma$ Decays

Inter-calibrating the electromagnetic calorimeter of the CMS detector {\it in situ} at the LHC to the design goal of $0.5\% $ precision is going to be important to fully exploit the physics reach of the detector, particularly for the discovery of the Higgs boson in the two-photon decay channel. In t...

Descripción completa

Detalles Bibliográficos
Autor principal: Yang, Y
Lenguaje:eng
Publicado: 2007
Materias:
Acceso en línea:https://dx.doi.org/10.1142/9789812819093_0068
http://cds.cern.ch/record/1096418
_version_ 1780913909881896960
author Yang, Y
author_facet Yang, Y
author_sort Yang, Y
collection CERN
description Inter-calibrating the electromagnetic calorimeter of the CMS detector {\it in situ} at the LHC to the design goal of $0.5\% $ precision is going to be important to fully exploit the physics reach of the detector, particularly for the discovery of the Higgs boson in the two-photon decay channel. In this paper we evaluate the potential of a novel calibration technique that makes use of photon pairs produced in neutral pion decays, $\pi^0 \rightarrow \gamma \gamma$. Such photon pairs will be selected from the QCD events accepted by the Level-1 triggers using an online filter farm. Assuming a Level-1 trigger rate of 12.5~kHz, the rate of suitable neutral pions is found to be about 0.9~kHz. We show that 95\% of the barrel electromagnetic calorimeter can be calibrated to at least 1\% (0.5\%) precision after several days (weeks) of data-taking in the low-luminosity scenario of LHC, $\mathcal{L} = 2 \cdot 10^{33} \, \mathrm{cm}^{-2}\,\mathrm{s}^{-1}$. In addition, we show that a 1\% calibration precision is achieved with $\pi^0$ decays produced in the $\pi^-$ test beam runs during November 2006. The obtained calibration constants are successfully used for the reconstruction of $50~GeV$ electrons from the test beam data.
id cern-1096418
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
record_format invenio
spelling cern-10964182019-09-30T06:29:59Zdoi:10.1142/9789812819093_0068http://cds.cern.ch/record/1096418engYang, YInter-calibration of the CMS Barrel Electromagnetic Calorimeter Using $\pi^0 \rightarrow \gamma\gamma$ DecaysDetectors and Experimental TechniquesInter-calibrating the electromagnetic calorimeter of the CMS detector {\it in situ} at the LHC to the design goal of $0.5\% $ precision is going to be important to fully exploit the physics reach of the detector, particularly for the discovery of the Higgs boson in the two-photon decay channel. In this paper we evaluate the potential of a novel calibration technique that makes use of photon pairs produced in neutral pion decays, $\pi^0 \rightarrow \gamma \gamma$. Such photon pairs will be selected from the QCD events accepted by the Level-1 triggers using an online filter farm. Assuming a Level-1 trigger rate of 12.5~kHz, the rate of suitable neutral pions is found to be about 0.9~kHz. We show that 95\% of the barrel electromagnetic calorimeter can be calibrated to at least 1\% (0.5\%) precision after several days (weeks) of data-taking in the low-luminosity scenario of LHC, $\mathcal{L} = 2 \cdot 10^{33} \, \mathrm{cm}^{-2}\,\mathrm{s}^{-1}$. In addition, we show that a 1\% calibration precision is achieved with $\pi^0$ decays produced in the $\pi^-$ test beam runs during November 2006. The obtained calibration constants are successfully used for the reconstruction of $50~GeV$ electrons from the test beam data.CMS-CR-2007-069oai:cds.cern.ch:10964182007-10-24
spellingShingle Detectors and Experimental Techniques
Yang, Y
Inter-calibration of the CMS Barrel Electromagnetic Calorimeter Using $\pi^0 \rightarrow \gamma\gamma$ Decays
title Inter-calibration of the CMS Barrel Electromagnetic Calorimeter Using $\pi^0 \rightarrow \gamma\gamma$ Decays
title_full Inter-calibration of the CMS Barrel Electromagnetic Calorimeter Using $\pi^0 \rightarrow \gamma\gamma$ Decays
title_fullStr Inter-calibration of the CMS Barrel Electromagnetic Calorimeter Using $\pi^0 \rightarrow \gamma\gamma$ Decays
title_full_unstemmed Inter-calibration of the CMS Barrel Electromagnetic Calorimeter Using $\pi^0 \rightarrow \gamma\gamma$ Decays
title_short Inter-calibration of the CMS Barrel Electromagnetic Calorimeter Using $\pi^0 \rightarrow \gamma\gamma$ Decays
title_sort inter-calibration of the cms barrel electromagnetic calorimeter using $\pi^0 \rightarrow \gamma\gamma$ decays
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1142/9789812819093_0068
http://cds.cern.ch/record/1096418
work_keys_str_mv AT yangy intercalibrationofthecmsbarrelelectromagneticcalorimeterusingpi0rightarrowgammagammadecays