Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment

In this presentation we describe the main design objectives, the detailed specifications and the final layout of the Detector Control System (DCS) for the electromagnetic calorimeter (ECAL) of the CMS experiment. Emphasis is put on the system implementation and specific hardware and software solutio...

Descripción completa

Detalles Bibliográficos
Autores principales: Adzic, P, Brett, A, Cavallari, F, Di Calafiori, D, Dissertori, G, Gómez-Reino, Robert, Inyakin, A, Jovanovic, D, Leshev, G, Milenovic, P, Ofierzynski, R, Punz, T, Puzovic, J, Zelepoukine, S
Lenguaje:eng
Publicado: CERN 2007
Materias:
Acceso en línea:https://dx.doi.org/10.5170/CERN-2007-007.100
http://cds.cern.ch/record/1096426
_version_ 1780913911630921728
author Adzic, P
Brett, A
Cavallari, F
Di Calafiori, D
Dissertori, G
Gómez-Reino, Robert
Inyakin, A
Jovanovic, D
Leshev, G
Milenovic, P
Ofierzynski, R
Punz, T
Puzovic, J
Zelepoukine, S
author_facet Adzic, P
Brett, A
Cavallari, F
Di Calafiori, D
Dissertori, G
Gómez-Reino, Robert
Inyakin, A
Jovanovic, D
Leshev, G
Milenovic, P
Ofierzynski, R
Punz, T
Puzovic, J
Zelepoukine, S
author_sort Adzic, P
collection CERN
description In this presentation we describe the main design objectives, the detailed specifications and the final layout of the Detector Control System (DCS) for the electromagnetic calorimeter (ECAL) of the CMS experiment. Emphasis is put on the system implementation and specific hardware and software solutions in each of its sub-systems. The latest results from the tests of final prototypes of these subsystems during the 2006 ECAL test-beam programme, as well as the installation and commissioning of the whole DCS at the CMS experimental construction site are discussed.
id cern-1096426
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2007
publisher CERN
record_format invenio
spelling cern-10964262019-09-30T06:29:59Zdoi:10.5170/CERN-2007-007.100http://cds.cern.ch/record/1096426engAdzic, PBrett, ACavallari, FDi Calafiori, DDissertori, GGómez-Reino, RobertInyakin, AJovanovic, DLeshev, GMilenovic, POfierzynski, RPunz, TPuzovic, JZelepoukine, SImplementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experimentDetectors and Experimental TechniquesIn this presentation we describe the main design objectives, the detailed specifications and the final layout of the Detector Control System (DCS) for the electromagnetic calorimeter (ECAL) of the CMS experiment. Emphasis is put on the system implementation and specific hardware and software solutions in each of its sub-systems. The latest results from the tests of final prototypes of these subsystems during the 2006 ECAL test-beam programme, as well as the installation and commissioning of the whole DCS at the CMS experimental construction site are discussed.CERNCMS-CR-2007-059oai:cds.cern.ch:10964262007-09-19
spellingShingle Detectors and Experimental Techniques
Adzic, P
Brett, A
Cavallari, F
Di Calafiori, D
Dissertori, G
Gómez-Reino, Robert
Inyakin, A
Jovanovic, D
Leshev, G
Milenovic, P
Ofierzynski, R
Punz, T
Puzovic, J
Zelepoukine, S
Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment
title Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment
title_full Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment
title_fullStr Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment
title_full_unstemmed Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment
title_short Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment
title_sort implementation and performance of the detector control system for the electromagnetic calorimeter of the cms experiment
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.5170/CERN-2007-007.100
http://cds.cern.ch/record/1096426
work_keys_str_mv AT adzicp implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT bretta implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT cavallarif implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT dicalafiorid implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT dissertorig implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT gomezreinorobert implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT inyakina implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT jovanovicd implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT leshevg implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT milenovicp implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT ofierzynskir implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT punzt implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT puzovicj implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment
AT zelepoukines implementationandperformanceofthedetectorcontrolsystemfortheelectromagneticcalorimeterofthecmsexperiment