Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules
The measurements presented in this paper are related to the development of a PET camera based on a 3-D axial geometry with excellent 3-D spatial, timing and energy resolution. The detector modules consist of matrices of long axially oriented scintillation crystal bars, which are individually coupled...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2007.11.022 http://cds.cern.ch/record/1096899 |
_version_ | 1780913916961882112 |
---|---|
author | Braem, André Chesi, Enrico Guido Joram, C Rudge, A Séguinot, Jacques Weilhammer, P De Leo, R Nappi, E Lustermann, W Schinzel, D Johnson, I Renker, D Albrecht, S |
author_facet | Braem, André Chesi, Enrico Guido Joram, C Rudge, A Séguinot, Jacques Weilhammer, P De Leo, R Nappi, E Lustermann, W Schinzel, D Johnson, I Renker, D Albrecht, S |
author_sort | Braem, André |
collection | CERN |
description | The measurements presented in this paper are related to the development of a PET camera based on a 3-D axial geometry with excellent 3-D spatial, timing and energy resolution. The detector modules consist of matrices of long axially oriented scintillation crystal bars, which are individually coupled to photodetectors. The axial coordinate is derived from wavelength shifting (WLS) plastic strips orthogonally interleaved between the crystal bars and readout by G-APD arrays. We report on results from measurements with two LYSO crystal bars, read with PMTs, and two WLS strips readout with G-APD devices from Hamamatsu (called MPPC). The WLS strips are positioned orthogonally underneath the LYSO bars. Yields of about 80 photoelectrons from the WLS strips for an energy deposition in the LYSO crystals equivalent to the absorption of 511 keV photons are observed. The axial coordinate in the LYSO bars is reconstructed with a precision of about 1.9 mm (FWHM) using a digital reconstruction method. The resolution of an analog coordinate reconstruction method, which uses the pulse height measurement from the WLS strips is 2.8 mm (FWHM). This resolution is still compromised by the availability of only two WLS strips and will improve with a full stack of LYSO crystals interleaved with WLS strip arrays, which is presently under development for a PET demonstrator set-up. |
id | cern-1096899 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
record_format | invenio |
spelling | cern-10968992019-09-30T06:29:59Zdoi:10.1016/j.nima.2007.11.022http://cds.cern.ch/record/1096899engBraem, AndréChesi, Enrico GuidoJoram, CRudge, ASéguinot, JacquesWeilhammer, PDe Leo, RNappi, ELustermann, WSchinzel, DJohnson, IRenker, DAlbrecht, SWavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modulesDetectors and Experimental TechniquesThe measurements presented in this paper are related to the development of a PET camera based on a 3-D axial geometry with excellent 3-D spatial, timing and energy resolution. The detector modules consist of matrices of long axially oriented scintillation crystal bars, which are individually coupled to photodetectors. The axial coordinate is derived from wavelength shifting (WLS) plastic strips orthogonally interleaved between the crystal bars and readout by G-APD arrays. We report on results from measurements with two LYSO crystal bars, read with PMTs, and two WLS strips readout with G-APD devices from Hamamatsu (called MPPC). The WLS strips are positioned orthogonally underneath the LYSO bars. Yields of about 80 photoelectrons from the WLS strips for an energy deposition in the LYSO crystals equivalent to the absorption of 511 keV photons are observed. The axial coordinate in the LYSO bars is reconstructed with a precision of about 1.9 mm (FWHM) using a digital reconstruction method. The resolution of an analog coordinate reconstruction method, which uses the pulse height measurement from the WLS strips is 2.8 mm (FWHM). This resolution is still compromised by the availability of only two WLS strips and will improve with a full stack of LYSO crystals interleaved with WLS strip arrays, which is presently under development for a PET demonstrator set-up.oai:cds.cern.ch:10968992008 |
spellingShingle | Detectors and Experimental Techniques Braem, André Chesi, Enrico Guido Joram, C Rudge, A Séguinot, Jacques Weilhammer, P De Leo, R Nappi, E Lustermann, W Schinzel, D Johnson, I Renker, D Albrecht, S Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules |
title | Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules |
title_full | Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules |
title_fullStr | Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules |
title_full_unstemmed | Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules |
title_short | Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules |
title_sort | wavelength shifter strips and g-apd arrays for the read-out of the z-coordinate in axial pet modules |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2007.11.022 http://cds.cern.ch/record/1096899 |
work_keys_str_mv | AT braemandre wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT chesienricoguido wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT joramc wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT rudgea wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT seguinotjacques wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT weilhammerp wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT deleor wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT nappie wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT lustermannw wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT schinzeld wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT johnsoni wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT renkerd wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules AT albrechts wavelengthshifterstripsandgapdarraysforthereadoutofthezcoordinateinaxialpetmodules |