Calibration of Cryogenic Thermometers for the LHC

6000 cryogenic temperature sensors of resistive type covering the range from room temperature down to 1.6 K are installed on the LHC machine. In order to meet the stringent requirements on temperature control of the superconducting magnets, each single sensor needs to be calibrated individually. In...

Descripción completa

Detalles Bibliográficos
Autores principales: Balle, Ch, Casas-Cubillos, J, Vauthier, N, Thermeau, JP
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:https://dx.doi.org/10.1063/1.2908696
http://cds.cern.ch/record/1099109
_version_ 1780913963629805568
author Balle, Ch
Casas-Cubillos, J
Vauthier, N
Thermeau, JP
author_facet Balle, Ch
Casas-Cubillos, J
Vauthier, N
Thermeau, JP
author_sort Balle, Ch
collection CERN
description 6000 cryogenic temperature sensors of resistive type covering the range from room temperature down to 1.6 K are installed on the LHC machine. In order to meet the stringent requirements on temperature control of the superconducting magnets, each single sensor needs to be calibrated individually. In the framework of a special contribution, IPN (Institut de Physique Nucléaire) in Orsay, France built and operated a calibration facility with a throughput of 80 thermometers per week. After reception from the manufacturer, the thermometer is first assembled onto a support specific to the measurement environment, and then thermally cycled ten times and calibrated at least once from 1.6 to 300 K. The procedure for each of these interventions includes various measurements and the acquired data is recorded in an ORACLE®-database. Furthermore random calibrations on some samples are executed at CERN to crosscheck the coherence between the approximation data obtained by both IPN and CERN. In the range of 1.5 K to 30 K, the calibration apparatuses at IPN and CERN are traceable to standards maintained in a national metrological laboratory by using a set of rhodium-iron temperature sensors of metrological quality. This paper presents the calibration procedure, the quality assurance applied, the results of the calibration campaigns and the return of experience.
id cern-1099109
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-10991092023-05-31T13:23:23Zdoi:10.1063/1.2908696http://cds.cern.ch/record/1099109engBalle, ChCasas-Cubillos, JVauthier, NThermeau, JPCalibration of Cryogenic Thermometers for the LHCAccelerators and Storage Rings6000 cryogenic temperature sensors of resistive type covering the range from room temperature down to 1.6 K are installed on the LHC machine. In order to meet the stringent requirements on temperature control of the superconducting magnets, each single sensor needs to be calibrated individually. In the framework of a special contribution, IPN (Institut de Physique Nucléaire) in Orsay, France built and operated a calibration facility with a throughput of 80 thermometers per week. After reception from the manufacturer, the thermometer is first assembled onto a support specific to the measurement environment, and then thermally cycled ten times and calibrated at least once from 1.6 to 300 K. The procedure for each of these interventions includes various measurements and the acquired data is recorded in an ORACLE®-database. Furthermore random calibrations on some samples are executed at CERN to crosscheck the coherence between the approximation data obtained by both IPN and CERN. In the range of 1.5 K to 30 K, the calibration apparatuses at IPN and CERN are traceable to standards maintained in a national metrological laboratory by using a set of rhodium-iron temperature sensors of metrological quality. This paper presents the calibration procedure, the quality assurance applied, the results of the calibration campaigns and the return of experience.LHC-PROJECT-Report-1077CERN-LHC-PROJECT-Report-1077oai:cds.cern.ch:10991092008
spellingShingle Accelerators and Storage Rings
Balle, Ch
Casas-Cubillos, J
Vauthier, N
Thermeau, JP
Calibration of Cryogenic Thermometers for the LHC
title Calibration of Cryogenic Thermometers for the LHC
title_full Calibration of Cryogenic Thermometers for the LHC
title_fullStr Calibration of Cryogenic Thermometers for the LHC
title_full_unstemmed Calibration of Cryogenic Thermometers for the LHC
title_short Calibration of Cryogenic Thermometers for the LHC
title_sort calibration of cryogenic thermometers for the lhc
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1063/1.2908696
http://cds.cern.ch/record/1099109
work_keys_str_mv AT ballech calibrationofcryogenicthermometersforthelhc
AT casascubillosj calibrationofcryogenicthermometersforthelhc
AT vauthiern calibrationofcryogenicthermometersforthelhc
AT thermeaujp calibrationofcryogenicthermometersforthelhc