Electric and magnetic field optimization procedure for Penning trap mass spectrometers

Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviat...

Descripción completa

Detalles Bibliográficos
Autores principales: Beck, D., Blaum, K., Bollen, G., Delahaye, P., George, S., Guenaut, C., Herfurth, F., Herlert, A., Lunney, D., Schweikhard, L., Yazidjian, C.
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2008.09.019
http://cds.cern.ch/record/1106975
_version_ 1780914125850804224
author Beck, D.
Blaum, K.
Bollen, G.
Delahaye, P.
George, S.
Guenaut, C.
Herfurth, F.
Herlert, A.
Lunney, D.
Schweikhard, L.
Yazidjian, C.
author_facet Beck, D.
Blaum, K.
Bollen, G.
Delahaye, P.
George, S.
Guenaut, C.
Herfurth, F.
Herlert, A.
Lunney, D.
Schweikhard, L.
Yazidjian, C.
author_sort Beck, D.
collection CERN
description Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.
id cern-1106975
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-11069752022-03-23T19:54:19Zdoi:10.1016/j.nima.2008.09.019http://cds.cern.ch/record/1106975engBeck, D.Blaum, K.Bollen, G.Delahaye, P.George, S.Guenaut, C.Herfurth, F.Herlert, A.Lunney, D.Schweikhard, L.Yazidjian, C.Electric and magnetic field optimization procedure for Penning trap mass spectrometersDetectors and Experimental TechniquesSignificant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.arXiv:0805.4549oai:cds.cern.ch:11069752008-05-30
spellingShingle Detectors and Experimental Techniques
Beck, D.
Blaum, K.
Bollen, G.
Delahaye, P.
George, S.
Guenaut, C.
Herfurth, F.
Herlert, A.
Lunney, D.
Schweikhard, L.
Yazidjian, C.
Electric and magnetic field optimization procedure for Penning trap mass spectrometers
title Electric and magnetic field optimization procedure for Penning trap mass spectrometers
title_full Electric and magnetic field optimization procedure for Penning trap mass spectrometers
title_fullStr Electric and magnetic field optimization procedure for Penning trap mass spectrometers
title_full_unstemmed Electric and magnetic field optimization procedure for Penning trap mass spectrometers
title_short Electric and magnetic field optimization procedure for Penning trap mass spectrometers
title_sort electric and magnetic field optimization procedure for penning trap mass spectrometers
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2008.09.019
http://cds.cern.ch/record/1106975
work_keys_str_mv AT beckd electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT blaumk electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT bolleng electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT delahayep electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT georges electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT guenautc electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT herfurthf electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT herlerta electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT lunneyd electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT schweikhardl electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers
AT yazidjianc electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers