Electric and magnetic field optimization procedure for Penning trap mass spectrometers
Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviat...
Autores principales: | , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2008.09.019 http://cds.cern.ch/record/1106975 |
_version_ | 1780914125850804224 |
---|---|
author | Beck, D. Blaum, K. Bollen, G. Delahaye, P. George, S. Guenaut, C. Herfurth, F. Herlert, A. Lunney, D. Schweikhard, L. Yazidjian, C. |
author_facet | Beck, D. Blaum, K. Bollen, G. Delahaye, P. George, S. Guenaut, C. Herfurth, F. Herlert, A. Lunney, D. Schweikhard, L. Yazidjian, C. |
author_sort | Beck, D. |
collection | CERN |
description | Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts. |
id | cern-1106975 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
record_format | invenio |
spelling | cern-11069752022-03-23T19:54:19Zdoi:10.1016/j.nima.2008.09.019http://cds.cern.ch/record/1106975engBeck, D.Blaum, K.Bollen, G.Delahaye, P.George, S.Guenaut, C.Herfurth, F.Herlert, A.Lunney, D.Schweikhard, L.Yazidjian, C.Electric and magnetic field optimization procedure for Penning trap mass spectrometersDetectors and Experimental TechniquesSignificant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap mass spectrometer ISOLTRAP, located at ISOLDE/CERN. The deviations from the ideal magnetic and electric fields are probed by measuring the cyclotron frequency and the reduced cyclotron frequency, respectively, of stored ions as a function of the time between the ejection of ions from the preparation trap and their capture in the precision trap, which influences the energy of their axial motion. The correction parameters are adjusted to minimize the frequency shifts.arXiv:0805.4549oai:cds.cern.ch:11069752008-05-30 |
spellingShingle | Detectors and Experimental Techniques Beck, D. Blaum, K. Bollen, G. Delahaye, P. George, S. Guenaut, C. Herfurth, F. Herlert, A. Lunney, D. Schweikhard, L. Yazidjian, C. Electric and magnetic field optimization procedure for Penning trap mass spectrometers |
title | Electric and magnetic field optimization procedure for Penning trap mass spectrometers |
title_full | Electric and magnetic field optimization procedure for Penning trap mass spectrometers |
title_fullStr | Electric and magnetic field optimization procedure for Penning trap mass spectrometers |
title_full_unstemmed | Electric and magnetic field optimization procedure for Penning trap mass spectrometers |
title_short | Electric and magnetic field optimization procedure for Penning trap mass spectrometers |
title_sort | electric and magnetic field optimization procedure for penning trap mass spectrometers |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2008.09.019 http://cds.cern.ch/record/1106975 |
work_keys_str_mv | AT beckd electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT blaumk electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT bolleng electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT delahayep electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT georges electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT guenautc electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT herfurthf electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT herlerta electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT lunneyd electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT schweikhardl electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers AT yazidjianc electricandmagneticfieldoptimizationprocedureforpenningtrapmassspectrometers |