Breakdown Voltage of the AC coupling oxide for a VELO sensor

The LHCb VELO sensors were systematically tested for their current-voltage (IV) characteristics, depletion voltage and problem channels [1]. Below we describe additional tests which measured the voltage at which the AC coupling oxide breaks down. As these tests are, by necessity, destructive only on...

Descripción completa

Detalles Bibliográficos
Autores principales: Turner, P R, Patel, G D
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:http://cds.cern.ch/record/1109348
_version_ 1780914253190922240
author Turner, P R
Patel, G D
author_facet Turner, P R
Patel, G D
author_sort Turner, P R
collection CERN
description The LHCb VELO sensors were systematically tested for their current-voltage (IV) characteristics, depletion voltage and problem channels [1]. Below we describe additional tests which measured the voltage at which the AC coupling oxide breaks down. As these tests are, by necessity, destructive only one sensor was fully characterized this way. For production purposes all sensors had each strip measured and the breakdown voltage is known to be > 40V /strip. The measurement of the breakdown voltage is especially important as it enables some estimates to be made of to be made of the tolerance of the VELO modules to intense beam spills.
id cern-1109348
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-11093482019-09-30T06:29:59Zhttp://cds.cern.ch/record/1109348engTurner, P RPatel, G DBreakdown Voltage of the AC coupling oxide for a VELO sensorDetectors and Experimental TechniquesThe LHCb VELO sensors were systematically tested for their current-voltage (IV) characteristics, depletion voltage and problem channels [1]. Below we describe additional tests which measured the voltage at which the AC coupling oxide breaks down. As these tests are, by necessity, destructive only one sensor was fully characterized this way. For production purposes all sensors had each strip measured and the breakdown voltage is known to be > 40V /strip. The measurement of the breakdown voltage is especially important as it enables some estimates to be made of to be made of the tolerance of the VELO modules to intense beam spills.LHCb-2008-029CERN-LHCb-2008-029oai:cds.cern.ch:11093482008-06-11
spellingShingle Detectors and Experimental Techniques
Turner, P R
Patel, G D
Breakdown Voltage of the AC coupling oxide for a VELO sensor
title Breakdown Voltage of the AC coupling oxide for a VELO sensor
title_full Breakdown Voltage of the AC coupling oxide for a VELO sensor
title_fullStr Breakdown Voltage of the AC coupling oxide for a VELO sensor
title_full_unstemmed Breakdown Voltage of the AC coupling oxide for a VELO sensor
title_short Breakdown Voltage of the AC coupling oxide for a VELO sensor
title_sort breakdown voltage of the ac coupling oxide for a velo sensor
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1109348
work_keys_str_mv AT turnerpr breakdownvoltageoftheaccouplingoxideforavelosensor
AT patelgd breakdownvoltageoftheaccouplingoxideforavelosensor