Cargando…
Difference in Stability Between Edge and Center in a Rutherford Cable
Keystoned superconducting Rutherford cables are widely used in accelerator magnets like in the LHC at CERN. An essential requirement in the cable design is its stability against local heat releases in the magnet windings originating from for example, strand movement or beam loss. Beam loss is the hi...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TASC.2008.920561 http://cds.cern.ch/record/1116079 |
_version_ | 1780914408402190336 |
---|---|
author | Willering, G P Verweij, A P Scheuerlein, C den Ouden, A ten Kate, H H J |
author_facet | Willering, G P Verweij, A P Scheuerlein, C den Ouden, A ten Kate, H H J |
author_sort | Willering, G P |
collection | CERN |
description | Keystoned superconducting Rutherford cables are widely used in accelerator magnets like in the LHC at CERN. An essential requirement in the cable design is its stability against local heat releases in the magnet windings originating from for example, strand movement or beam loss. Beam loss is the highest at the coil inner radius of the magnet, where also the magnetic field peaks. Also the local compaction of the cable is maximum here and hence the helium content minimum. When performing stability measurements on several superconducting Nb-Ti cables used in LHC dipole and quadrupole magnets, we observed that the stability against point-like heat disturbances is much worse very close to the cable edges as compared to the central part of the cable. The main reason is related to the geometry of the cable causing variation of many parameters across the cable width, like inter-strand electrical resistance, inter-strand heat conductivity, cooled strand surfaces and RRR. In this paper we show results of new stability experiments and thoroughly compare the data with results obtained with the numerical network model CUDI, which is updated for stability simulations. |
id | cern-1116079 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
record_format | invenio |
spelling | cern-11160792019-09-30T06:29:59Zdoi:10.1109/TASC.2008.920561http://cds.cern.ch/record/1116079engWillering, G PVerweij, A PScheuerlein, Cden Ouden, Aten Kate, H H JDifference in Stability Between Edge and Center in a Rutherford CableAccelerators and Storage RingsKeystoned superconducting Rutherford cables are widely used in accelerator magnets like in the LHC at CERN. An essential requirement in the cable design is its stability against local heat releases in the magnet windings originating from for example, strand movement or beam loss. Beam loss is the highest at the coil inner radius of the magnet, where also the magnetic field peaks. Also the local compaction of the cable is maximum here and hence the helium content minimum. When performing stability measurements on several superconducting Nb-Ti cables used in LHC dipole and quadrupole magnets, we observed that the stability against point-like heat disturbances is much worse very close to the cable edges as compared to the central part of the cable. The main reason is related to the geometry of the cable causing variation of many parameters across the cable width, like inter-strand electrical resistance, inter-strand heat conductivity, cooled strand surfaces and RRR. In this paper we show results of new stability experiments and thoroughly compare the data with results obtained with the numerical network model CUDI, which is updated for stability simulations.CERN-AT-2008-010oai:cds.cern.ch:11160792008-07-11 |
spellingShingle | Accelerators and Storage Rings Willering, G P Verweij, A P Scheuerlein, C den Ouden, A ten Kate, H H J Difference in Stability Between Edge and Center in a Rutherford Cable |
title | Difference in Stability Between Edge and Center in a Rutherford Cable |
title_full | Difference in Stability Between Edge and Center in a Rutherford Cable |
title_fullStr | Difference in Stability Between Edge and Center in a Rutherford Cable |
title_full_unstemmed | Difference in Stability Between Edge and Center in a Rutherford Cable |
title_short | Difference in Stability Between Edge and Center in a Rutherford Cable |
title_sort | difference in stability between edge and center in a rutherford cable |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1109/TASC.2008.920561 http://cds.cern.ch/record/1116079 |
work_keys_str_mv | AT willeringgp differenceinstabilitybetweenedgeandcenterinarutherfordcable AT verweijap differenceinstabilitybetweenedgeandcenterinarutherfordcable AT scheuerleinc differenceinstabilitybetweenedgeandcenterinarutherfordcable AT denoudena differenceinstabilitybetweenedgeandcenterinarutherfordcable AT tenkatehhj differenceinstabilitybetweenedgeandcenterinarutherfordcable |