Cargando…
Dependence of the Static and Dynamic Field Quality of the LHC Superconducting Dipole Magnets on the Pre-Cycle Ramp Rate
The allowed multipoles in the Large Hadron Collider (LHC) superconducting dipole magnets decay whilst on a constant current plateau. It is known that the decay amplitude is largely affected by the powering history of the magnet, and particularly by the pre-cycle flat top current and duration and the...
Autores principales: | Sammut, N J, Bottura, L, Deferne, G, Venturini-Delsolaro, W, Wolf, R |
---|---|