Cargando…
Study of a spectrometer line for the Linac4 diagnostics movable bench
movable diagnostics bench is currently being designed as part of the Linac4 commissioning plan to characterise the H-beam at the exit of each DTL tank. A spectrometer line has been proposed for installation on the bench to allow performing measurements of the beam energy spread with a slit/dipole/mo...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1133143 |
_version_ | 1780915370873323520 |
---|---|
author | Bellodi, G Lombardi, A |
author_facet | Bellodi, G Lombardi, A |
author_sort | Bellodi, G |
collection | CERN |
description | movable diagnostics bench is currently being designed as part of the Linac4 commissioning plan to characterise the H-beam at the exit of each DTL tank. A spectrometer line has been proposed for installation on the bench to allow performing measurements of the beam energy spread with a slit/dipole/monitor technique. A layout for this diagnostics line is here proposed together with the results of beam dynamics studies to evaluate the resolution achievable and the measurement reach. |
id | cern-1133143 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
record_format | invenio |
spelling | cern-11331432019-09-30T06:29:59Zhttp://cds.cern.ch/record/1133143engBellodi, GLombardi, AStudy of a spectrometer line for the Linac4 diagnostics movable benchAccelerators and Storage Ringsmovable diagnostics bench is currently being designed as part of the Linac4 commissioning plan to characterise the H-beam at the exit of each DTL tank. A spectrometer line has been proposed for installation on the bench to allow performing measurements of the beam energy spread with a slit/dipole/monitor technique. A layout for this diagnostics line is here proposed together with the results of beam dynamics studies to evaluate the resolution achievable and the measurement reach.CERN-AB-Note-2008-046oai:cds.cern.ch:11331432008-09-30 |
spellingShingle | Accelerators and Storage Rings Bellodi, G Lombardi, A Study of a spectrometer line for the Linac4 diagnostics movable bench |
title | Study of a spectrometer line for the Linac4 diagnostics movable bench |
title_full | Study of a spectrometer line for the Linac4 diagnostics movable bench |
title_fullStr | Study of a spectrometer line for the Linac4 diagnostics movable bench |
title_full_unstemmed | Study of a spectrometer line for the Linac4 diagnostics movable bench |
title_short | Study of a spectrometer line for the Linac4 diagnostics movable bench |
title_sort | study of a spectrometer line for the linac4 diagnostics movable bench |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1133143 |
work_keys_str_mv | AT bellodig studyofaspectrometerlineforthelinac4diagnosticsmovablebench AT lombardia studyofaspectrometerlineforthelinac4diagnosticsmovablebench |