Cargando…
Performance of CMS ECAL Preshower in 2007 test beam
The Preshower detector is part of the CMS Electromagnetic Calorimeter, located in the endcap regions, in front of the lead tungstate crystals. It consist of two orthogonal planes of silicon strip sensors interleaved with two planes of lead absorbers. A combined beam test of close-to-final prototypes...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1133590 |
_version_ | 1780915378882347008 |
---|---|
author | Li, Syue-Wei Go, Apollo Kuo, Chia-Ming |
author_facet | Li, Syue-Wei Go, Apollo Kuo, Chia-Ming |
author_sort | Li, Syue-Wei |
collection | CERN |
description | The Preshower detector is part of the CMS Electromagnetic Calorimeter, located in the endcap regions, in front of the lead tungstate crystals. It consist of two orthogonal planes of silicon strip sensors interleaved with two planes of lead absorbers. A combined beam test of close-to-final prototypes of the Hadron calorimeter, the crystal calorimeter and the Preshower detector was performed in the summer of 2007. Calibrations were made using electron and pion data. The combined crystal and Preshower energy resolution was studied using electrons. Good signal/noise performance was obtained in both sets of measurements |
id | cern-1133590 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
record_format | invenio |
spelling | cern-11335902019-09-30T06:29:59Zhttp://cds.cern.ch/record/1133590engLi, Syue-WeiGo, ApolloKuo, Chia-MingPerformance of CMS ECAL Preshower in 2007 test beamDetectors and Experimental TechniquesThe Preshower detector is part of the CMS Electromagnetic Calorimeter, located in the endcap regions, in front of the lead tungstate crystals. It consist of two orthogonal planes of silicon strip sensors interleaved with two planes of lead absorbers. A combined beam test of close-to-final prototypes of the Hadron calorimeter, the crystal calorimeter and the Preshower detector was performed in the summer of 2007. Calibrations were made using electron and pion data. The combined crystal and Preshower energy resolution was studied using electrons. Good signal/noise performance was obtained in both sets of measurementsCMS-CR-2008-057oai:cds.cern.ch:11335902008-09-02 |
spellingShingle | Detectors and Experimental Techniques Li, Syue-Wei Go, Apollo Kuo, Chia-Ming Performance of CMS ECAL Preshower in 2007 test beam |
title | Performance of CMS ECAL Preshower in 2007 test beam |
title_full | Performance of CMS ECAL Preshower in 2007 test beam |
title_fullStr | Performance of CMS ECAL Preshower in 2007 test beam |
title_full_unstemmed | Performance of CMS ECAL Preshower in 2007 test beam |
title_short | Performance of CMS ECAL Preshower in 2007 test beam |
title_sort | performance of cms ecal preshower in 2007 test beam |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1133590 |
work_keys_str_mv | AT lisyuewei performanceofcmsecalpreshowerin2007testbeam AT goapollo performanceofcmsecalpreshowerin2007testbeam AT kuochiaming performanceofcmsecalpreshowerin2007testbeam |