Cargando…

Performance of CMS ECAL Preshower in 2007 test beam

The Preshower detector is part of the CMS Electromagnetic Calorimeter, located in the endcap regions, in front of the lead tungstate crystals. It consist of two orthogonal planes of silicon strip sensors interleaved with two planes of lead absorbers. A combined beam test of close-to-final prototypes...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Syue-Wei, Go, Apollo, Kuo, Chia-Ming
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:http://cds.cern.ch/record/1133590
_version_ 1780915378882347008
author Li, Syue-Wei
Go, Apollo
Kuo, Chia-Ming
author_facet Li, Syue-Wei
Go, Apollo
Kuo, Chia-Ming
author_sort Li, Syue-Wei
collection CERN
description The Preshower detector is part of the CMS Electromagnetic Calorimeter, located in the endcap regions, in front of the lead tungstate crystals. It consist of two orthogonal planes of silicon strip sensors interleaved with two planes of lead absorbers. A combined beam test of close-to-final prototypes of the Hadron calorimeter, the crystal calorimeter and the Preshower detector was performed in the summer of 2007. Calibrations were made using electron and pion data. The combined crystal and Preshower energy resolution was studied using electrons. Good signal/noise performance was obtained in both sets of measurements
id cern-1133590
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-11335902019-09-30T06:29:59Zhttp://cds.cern.ch/record/1133590engLi, Syue-WeiGo, ApolloKuo, Chia-MingPerformance of CMS ECAL Preshower in 2007 test beamDetectors and Experimental TechniquesThe Preshower detector is part of the CMS Electromagnetic Calorimeter, located in the endcap regions, in front of the lead tungstate crystals. It consist of two orthogonal planes of silicon strip sensors interleaved with two planes of lead absorbers. A combined beam test of close-to-final prototypes of the Hadron calorimeter, the crystal calorimeter and the Preshower detector was performed in the summer of 2007. Calibrations were made using electron and pion data. The combined crystal and Preshower energy resolution was studied using electrons. Good signal/noise performance was obtained in both sets of measurementsCMS-CR-2008-057oai:cds.cern.ch:11335902008-09-02
spellingShingle Detectors and Experimental Techniques
Li, Syue-Wei
Go, Apollo
Kuo, Chia-Ming
Performance of CMS ECAL Preshower in 2007 test beam
title Performance of CMS ECAL Preshower in 2007 test beam
title_full Performance of CMS ECAL Preshower in 2007 test beam
title_fullStr Performance of CMS ECAL Preshower in 2007 test beam
title_full_unstemmed Performance of CMS ECAL Preshower in 2007 test beam
title_short Performance of CMS ECAL Preshower in 2007 test beam
title_sort performance of cms ecal preshower in 2007 test beam
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1133590
work_keys_str_mv AT lisyuewei performanceofcmsecalpreshowerin2007testbeam
AT goapollo performanceofcmsecalpreshowerin2007testbeam
AT kuochiaming performanceofcmsecalpreshowerin2007testbeam