Cargando…
Testing and calibrating analogue inputs to the ATLAS Level-1 Calorimeter Trigger
The ATLAS Level-1 Calorimeter Trigger is a hardwarebased system which aims to identify objects with high transverse momentum within an overall latency of 2.5 μs. It is composed of a PreProcessor system (PPr) which digitises 7200 analogue input channels, determines the bunch crossing of the interact...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
2008
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-2008-008.467 http://cds.cern.ch/record/1138900 |
Sumario: | The ATLAS Level-1 Calorimeter Trigger is a hardwarebased system which aims to identify objects with high transverse momentum within an overall latency of 2.5 μs. It is composed of a PreProcessor system (PPr) which digitises 7200 analogue input channels, determines the bunch crossing of the interaction, applies a digital noise filter, and provides a fine calibration; and two subsequent digital processors. The PreProcessor system needs various channel dependent parameters to be set in order to provide digital signals which are aligned in time and have proper energy calibration. The different techniques which are used to derive these parameters are described along with the quality tests of the analogue input signals. |
---|