Cargando…

Calibration of a Highly Granular Hadronic Calorimeter with SiPM Readout

A highly granular hadronic calorimeter (HCAL) based on scintillator tiles with individual readout by silicon photomultipliers (SiPMs) has been constructed by the CALICE collaboration and has been tested extensively in particle beams at CERN. The 7608 SiPMs coupled to scintillator tiles in the approx...

Descripción completa

Detalles Bibliográficos
Autor principal: Simon, Frank
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:https://dx.doi.org/10.1109/NSSMIC.2008.4774798
http://cds.cern.ch/record/1140180
_version_ 1780915532231344128
author Simon, Frank
author_facet Simon, Frank
author_sort Simon, Frank
collection CERN
description A highly granular hadronic calorimeter (HCAL) based on scintillator tiles with individual readout by silicon photomultipliers (SiPMs) has been constructed by the CALICE collaboration and has been tested extensively in particle beams at CERN. The 7608 SiPMs coupled to scintillator tiles in the approximately 1 cubic meter large calorimeter allow large sample studies of behavior of these devices under varying voltage and temperature as well as their saturation behavior. We also present detailed studies of the temperature dependence of the calorimeter signal in muon and hadron beams. The calibration of the full calorimeter using muons is discussed. In addition, a novel method for calibration and detector studies using minimum-ionizing track segments in hadronic showers, is explored.
id cern-1140180
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-11401802021-05-03T20:06:21Zdoi:10.1109/NSSMIC.2008.4774798http://cds.cern.ch/record/1140180engSimon, FrankCalibration of a Highly Granular Hadronic Calorimeter with SiPM Readoutphysics.ins-detA highly granular hadronic calorimeter (HCAL) based on scintillator tiles with individual readout by silicon photomultipliers (SiPMs) has been constructed by the CALICE collaboration and has been tested extensively in particle beams at CERN. The 7608 SiPMs coupled to scintillator tiles in the approximately 1 cubic meter large calorimeter allow large sample studies of behavior of these devices under varying voltage and temperature as well as their saturation behavior. We also present detailed studies of the temperature dependence of the calorimeter signal in muon and hadron beams. The calibration of the full calorimeter using muons is discussed. In addition, a novel method for calibration and detector studies using minimum-ionizing track segments in hadronic showers, is explored.A highly granular hadronic calorimeter (HCAL) based on scintillator tiles with individual readout by silicon photomultipliers (SiPMs) has been constructed by the CALICE collaboration and has been tested extensively in particle beams at CERN. The 7608 SiPMs coupled to scintillator tiles in the approximately 1 cubic meter large calorimeter allow large sample studies of behavior of these devices under varying voltage and temperature as well as their saturation behavior. We also present detailed studies of the temperature dependence of the calorimeter signal in muon and hadron beams. The calibration of the full calorimeter using muons is discussed. In addition, a novel method for calibration and detector studies using minimum-ionizing track segments in hadronic showers, is explored.arXiv:0811.2431oai:cds.cern.ch:11401802008-11-18
spellingShingle physics.ins-det
Simon, Frank
Calibration of a Highly Granular Hadronic Calorimeter with SiPM Readout
title Calibration of a Highly Granular Hadronic Calorimeter with SiPM Readout
title_full Calibration of a Highly Granular Hadronic Calorimeter with SiPM Readout
title_fullStr Calibration of a Highly Granular Hadronic Calorimeter with SiPM Readout
title_full_unstemmed Calibration of a Highly Granular Hadronic Calorimeter with SiPM Readout
title_short Calibration of a Highly Granular Hadronic Calorimeter with SiPM Readout
title_sort calibration of a highly granular hadronic calorimeter with sipm readout
topic physics.ins-det
url https://dx.doi.org/10.1109/NSSMIC.2008.4774798
http://cds.cern.ch/record/1140180
work_keys_str_mv AT simonfrank calibrationofahighlygranularhadroniccalorimeterwithsipmreadout