Cargando…

Water data analysis: data reduction from beam and ITC info

After recalling the motivation for the analysis of water data, the first stage of data reduction is discussed. This data reduction is based on the selection of protons using beam detector data and ITC information. The resolution of the interaction time in the target which serves as reference for tim...

Descripción completa

Detalles Bibliográficos
Autores principales: Chelkov, G, De Min, A, Dydak, F, Gostkin, M, Guskov, A, Nefedov, Y, Wotschack, J, Zhemchugov, A
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/1142704
_version_ 1780915616242204672
author Chelkov, G
De Min, A
Dydak, F
Gostkin, M
Guskov, A
Nefedov, Y
Wotschack, J
Zhemchugov, A
author_facet Chelkov, G
De Min, A
Dydak, F
Gostkin, M
Guskov, A
Nefedov, Y
Wotschack, J
Zhemchugov, A
author_sort Chelkov, G
collection CERN
description After recalling the motivation for the analysis of water data, the first stage of data reduction is discussed. This data reduction is based on the selection of protons using beam detector data and ITC information. The resolution of the interaction time in the target which serves as reference for time-of-flight measurement of secondaries, is determined with stable beam optics to be 77 ps, otherwise 106 ps. Cuts, their selection efficiency, event numbers, purity of the data sample after cuts, and some ITC characteristics are presented.
id cern-1142704
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-11427042019-09-30T06:29:59Zhttp://cds.cern.ch/record/1142704engChelkov, GDe Min, ADydak, FGostkin, MGuskov, ANefedov, YWotschack, JZhemchugov, AWater data analysis: data reduction from beam and ITC infoDetectors and Experimental TechniquesAfter recalling the motivation for the analysis of water data, the first stage of data reduction is discussed. This data reduction is based on the selection of protons using beam detector data and ITC information. The resolution of the interaction time in the target which serves as reference for time-of-flight measurement of secondaries, is determined with stable beam optics to be 77 ps, otherwise 106 ps. Cuts, their selection efficiency, event numbers, purity of the data sample after cuts, and some ITC characteristics are presented.CERN-HARP-CDP-2004-004HARP Memo 04-001oai:cds.cern.ch:11427042004-05-20
spellingShingle Detectors and Experimental Techniques
Chelkov, G
De Min, A
Dydak, F
Gostkin, M
Guskov, A
Nefedov, Y
Wotschack, J
Zhemchugov, A
Water data analysis: data reduction from beam and ITC info
title Water data analysis: data reduction from beam and ITC info
title_full Water data analysis: data reduction from beam and ITC info
title_fullStr Water data analysis: data reduction from beam and ITC info
title_full_unstemmed Water data analysis: data reduction from beam and ITC info
title_short Water data analysis: data reduction from beam and ITC info
title_sort water data analysis: data reduction from beam and itc info
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1142704
work_keys_str_mv AT chelkovg waterdataanalysisdatareductionfrombeamanditcinfo
AT demina waterdataanalysisdatareductionfrombeamanditcinfo
AT dydakf waterdataanalysisdatareductionfrombeamanditcinfo
AT gostkinm waterdataanalysisdatareductionfrombeamanditcinfo
AT guskova waterdataanalysisdatareductionfrombeamanditcinfo
AT nefedovy waterdataanalysisdatareductionfrombeamanditcinfo
AT wotschackj waterdataanalysisdatareductionfrombeamanditcinfo
AT zhemchugova waterdataanalysisdatareductionfrombeamanditcinfo