Water data: bad TPC pads, 3.6 µs and 100 ns problems

Out of the 3972 pads of the HARP TPC, about 9% are 'bad' and not useful for the correct reconstruction of clusters. Bad pads comprise dead pads, noisy pads, and pads with low or undefined amplification. Pads may be bad at one time, but not at another. This memo discusses the sources of inf...

Descripción completa

Detalles Bibliográficos
Autores principales: Dydak, F, Gostkin, M, Nefedov, Y, Wotschack, J, Zhemchugov, A
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/1142705
_version_ 1780915616449822720
author Dydak, F
Gostkin, M
Nefedov, Y
Wotschack, J
Zhemchugov, A
author_facet Dydak, F
Gostkin, M
Nefedov, Y
Wotschack, J
Zhemchugov, A
author_sort Dydak, F
collection CERN
description Out of the 3972 pads of the HARP TPC, about 9% are 'bad' and not useful for the correct reconstruction of clusters. Bad pads comprise dead pads, noisy pads, and pads with low or undefined amplification. Pads may be bad at one time, but not at another. This memo discusses the sources of information which were used to declare a pad 'bad', and gives the list of bad pads for the water data (runs 19146 to 19301). Also, the 3.6 µs and 100 ns problems of the TPC readout are discussed, including the corrective measures which have been taken.
id cern-1142705
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-11427052019-09-30T06:29:59Zhttp://cds.cern.ch/record/1142705engDydak, FGostkin, MNefedov, YWotschack, JZhemchugov, AWater data: bad TPC pads, 3.6 µs and 100 ns problemsDetectors and Experimental TechniquesOut of the 3972 pads of the HARP TPC, about 9% are 'bad' and not useful for the correct reconstruction of clusters. Bad pads comprise dead pads, noisy pads, and pads with low or undefined amplification. Pads may be bad at one time, but not at another. This memo discusses the sources of information which were used to declare a pad 'bad', and gives the list of bad pads for the water data (runs 19146 to 19301). Also, the 3.6 µs and 100 ns problems of the TPC readout are discussed, including the corrective measures which have been taken.CERN-HARP-CDP-2004-005HARP Memo 04-104oai:cds.cern.ch:11427052004-05-27
spellingShingle Detectors and Experimental Techniques
Dydak, F
Gostkin, M
Nefedov, Y
Wotschack, J
Zhemchugov, A
Water data: bad TPC pads, 3.6 µs and 100 ns problems
title Water data: bad TPC pads, 3.6 µs and 100 ns problems
title_full Water data: bad TPC pads, 3.6 µs and 100 ns problems
title_fullStr Water data: bad TPC pads, 3.6 µs and 100 ns problems
title_full_unstemmed Water data: bad TPC pads, 3.6 µs and 100 ns problems
title_short Water data: bad TPC pads, 3.6 µs and 100 ns problems
title_sort water data: bad tpc pads, 3.6 âµs and 100 ns problems
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1142705
work_keys_str_mv AT dydakf waterdatabadtpcpads36aμsand100nsproblems
AT gostkinm waterdatabadtpcpads36aμsand100nsproblems
AT nefedovy waterdatabadtpcpads36aμsand100nsproblems
AT wotschackj waterdatabadtpcpads36aμsand100nsproblems
AT zhemchugova waterdatabadtpcpads36aμsand100nsproblems