Cargando…
Pad equalization and dE/dx in the HARP TPC
In the HARP TPC, the specific ionization dE/dx depends critically on the pad equalization, which in turn depends on the crosstalk correction. We discuss the TPC pad equalization algorithm and its performance in terms of average and resolution of dE/dx of negative pions with an average active track l...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2006
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1143018 |
_version_ | 1780915624650735616 |
---|---|
author | Ammosov, V Boyko, I Chelkov, G Dedovitch, D Dydak, F Elagin, A Gostkin, M Guskov, A Koreshev, V Krumshtein, Z Nefedov, Y Nikolaev, K Wotschack, J Zhemchugov, A |
author_facet | Ammosov, V Boyko, I Chelkov, G Dedovitch, D Dydak, F Elagin, A Gostkin, M Guskov, A Koreshev, V Krumshtein, Z Nefedov, Y Nikolaev, K Wotschack, J Zhemchugov, A |
author_sort | Ammosov, V |
collection | CERN |
description | In the HARP TPC, the specific ionization dE/dx depends critically on the pad equalization, which in turn depends on the crosstalk correction. We discuss the TPC pad equalization algorithm and its performance in terms of average and resolution of dE/dx of negative pions with an average active track length of 300 mm. The observed dE/dx of pions and protons agrees satisfactorily with the theoretical expectation, the resolution for a minimum-ionizing track length of 300 mm is 16%. |
id | cern-1143018 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2006 |
record_format | invenio |
spelling | cern-11430182019-09-30T06:29:59Zhttp://cds.cern.ch/record/1143018engAmmosov, VBoyko, IChelkov, GDedovitch, DDydak, FElagin, AGostkin, MGuskov, AKoreshev, VKrumshtein, ZNefedov, YNikolaev, KWotschack, JZhemchugov, APad equalization and dE/dx in the HARP TPCDetectors and Experimental TechniquesIn the HARP TPC, the specific ionization dE/dx depends critically on the pad equalization, which in turn depends on the crosstalk correction. We discuss the TPC pad equalization algorithm and its performance in terms of average and resolution of dE/dx of negative pions with an average active track length of 300 mm. The observed dE/dx of pions and protons agrees satisfactorily with the theoretical expectation, the resolution for a minimum-ionizing track length of 300 mm is 16%.CERN-HARP-CDP-2006-006HARP Memo 06-104oai:cds.cern.ch:11430182006-10-19 |
spellingShingle | Detectors and Experimental Techniques Ammosov, V Boyko, I Chelkov, G Dedovitch, D Dydak, F Elagin, A Gostkin, M Guskov, A Koreshev, V Krumshtein, Z Nefedov, Y Nikolaev, K Wotschack, J Zhemchugov, A Pad equalization and dE/dx in the HARP TPC |
title | Pad equalization and dE/dx in the HARP TPC |
title_full | Pad equalization and dE/dx in the HARP TPC |
title_fullStr | Pad equalization and dE/dx in the HARP TPC |
title_full_unstemmed | Pad equalization and dE/dx in the HARP TPC |
title_short | Pad equalization and dE/dx in the HARP TPC |
title_sort | pad equalization and de/dx in the harp tpc |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1143018 |
work_keys_str_mv | AT ammosovv padequalizationanddedxintheharptpc AT boykoi padequalizationanddedxintheharptpc AT chelkovg padequalizationanddedxintheharptpc AT dedovitchd padequalizationanddedxintheharptpc AT dydakf padequalizationanddedxintheharptpc AT elagina padequalizationanddedxintheharptpc AT gostkinm padequalizationanddedxintheharptpc AT guskova padequalizationanddedxintheharptpc AT koreshevv padequalizationanddedxintheharptpc AT krumshteinz padequalizationanddedxintheharptpc AT nefedovy padequalizationanddedxintheharptpc AT nikolaevk padequalizationanddedxintheharptpc AT wotschackj padequalizationanddedxintheharptpc AT zhemchugova padequalizationanddedxintheharptpc |