Cargando…
SPS Machine Protection Incident in 2009
During the 008 SPS run a single machine operation incident happened on June 27th when a high intensity CNGS beam was lost in a dipole of sextant 1 following a time system ‘freeze’. The vacuum chamber was punctured over a length of over 10 cm, and the vacuum in the affected sector rose to atmospheric...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2009
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1156141 |
Sumario: | During the 008 SPS run a single machine operation incident happened on June 27th when a high intensity CNGS beam was lost in a dipole of sextant 1 following a time system ‘freeze’. The vacuum chamber was punctured over a length of over 10 cm, and the vacuum in the affected sector rose to atmospheric pressure. The dipole was exchanged June 30th. This note describes the incident in detail and presents the measures taken to avoid a similar incident in the future. |
---|