Cargando…

Status of the CALICE DAQ system

A data acquisition (DAQ) system is described which will be used for the next generation of prototype calorimeters using particle flow algorithms for the International Linear Collider (ILC). The design is sufficiently generic and scalable such that it should have numerous applications either for ILC...

Descripción completa

Detalles Bibliográficos
Autor principal: Bartsch, Valeria
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1157775
Descripción
Sumario:A data acquisition (DAQ) system is described which will be used for the next generation of prototype calorimeters using particle flow algorithms for the International Linear Collider (ILC). The design is sufficiently generic and scalable such that it should have numerous applications either for ILC detectors or elsewhere within high energy physics in general. The DAQ system will be implemented using FPGAs and built using off-the-shelf components and networking hardware with programmable FPGAs. The software for the DAQ system is based on an existing framework, DOOCS, which is a server/client object-oriented system. The design philosophy, current status of the project and its aims are presented in this report.