Power Distribution in a CMS Tracker for the SLHC
An upgraded tracker for CMS will need a new architecture for powering to keep the power dissipated in the power cables to acceptable levels. Inductor topologies to reduce the stray magnetic field are discussed together with measurements of the magnetic field produced by prototype inductors. A transf...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
2008
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-2008-008.522 http://cds.cern.ch/record/1159886 |
_version_ | 1780915855270346752 |
---|---|
author | Cussans, D G Ford, G P Hill, C |
author_facet | Cussans, D G Ford, G P Hill, C |
author_sort | Cussans, D G |
collection | CERN |
description | An upgraded tracker for CMS will need a new architecture for powering to keep the power dissipated in the power cables to acceptable levels. Inductor topologies to reduce the stray magnetic field are discussed together with measurements of the magnetic field produced by prototype inductors. A transformer based DC-DC converter has the potential to produce a high stepdown ratio whilst producing a low stray field and retaining high efficiency. The relative merits of buck configuration and transformer based DC-DC converters are discussed. |
id | cern-1159886 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
publisher | CERN |
record_format | invenio |
spelling | cern-11598862019-09-30T06:29:59Zdoi:10.5170/CERN-2008-008.522http://cds.cern.ch/record/1159886engCussans, D GFord, G PHill, CPower Distribution in a CMS Tracker for the SLHCDetectors and Experimental TechniquesAn upgraded tracker for CMS will need a new architecture for powering to keep the power dissipated in the power cables to acceptable levels. Inductor topologies to reduce the stray magnetic field are discussed together with measurements of the magnetic field produced by prototype inductors. A transformer based DC-DC converter has the potential to produce a high stepdown ratio whilst producing a low stray field and retaining high efficiency. The relative merits of buck configuration and transformer based DC-DC converters are discussed.CERNoai:cds.cern.ch:11598862008 |
spellingShingle | Detectors and Experimental Techniques Cussans, D G Ford, G P Hill, C Power Distribution in a CMS Tracker for the SLHC |
title | Power Distribution in a CMS Tracker for the SLHC |
title_full | Power Distribution in a CMS Tracker for the SLHC |
title_fullStr | Power Distribution in a CMS Tracker for the SLHC |
title_full_unstemmed | Power Distribution in a CMS Tracker for the SLHC |
title_short | Power Distribution in a CMS Tracker for the SLHC |
title_sort | power distribution in a cms tracker for the slhc |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.5170/CERN-2008-008.522 http://cds.cern.ch/record/1159886 |
work_keys_str_mv | AT cussansdg powerdistributioninacmstrackerfortheslhc AT fordgp powerdistributioninacmstrackerfortheslhc AT hillc powerdistributioninacmstrackerfortheslhc |