An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently u...

Descripción completa

Detalles Bibliográficos
Autores principales: Wendt, M., Lefevre, T., Simon, C., Vilalte, S.
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1162430
_version_ 1780915937467170816
author Wendt, M.
Lefevre, T.
Simon, C.
Vilalte, S.
author_facet Wendt, M.
Lefevre, T.
Simon, C.
Vilalte, S.
author_sort Wendt, M.
collection CERN
description An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently under investigation: A resonant dipole-mode cavity-style BPM pickup, developed at Fermilab, and a re-entrant resonant coaxial waveguide BPM, designed by CEA-Saclay. While the 1.5 GHz dipole-mode cavity BPM is still in the R&D phase, the re-entrant BPM has already passed first beam tests, including its read-out system. Furthermore, the LAPP group is developing radiation tolerant digital read-out systems, which are tested at the CLIC test facility (CTF).
id cern-1162430
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-11624302023-01-31T10:07:34Zhttp://cds.cern.ch/record/1162430engWendt, M.Lefevre, T.Simon, C.Vilalte, S.Status of the ILC Main Linac BPM R&Dphysics.acc-phAn introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently under investigation: A resonant dipole-mode cavity-style BPM pickup, developed at Fermilab, and a re-entrant resonant coaxial waveguide BPM, designed by CEA-Saclay. While the 1.5 GHz dipole-mode cavity BPM is still in the R&D phase, the re-entrant BPM has already passed first beam tests, including its read-out system. Furthermore, the LAPP group is developing radiation tolerant digital read-out systems, which are tested at the CLIC test facility (CTF).An introduction and the status of R&D activities for a high-resolution, 'cold' beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently under investigation: A resonant dipole-mode cavity-style BPM pickup, developed at Fermilab, and a re-entrant resonant coaxial waveguide BPM, designed by CEA-Saclay. While the 1.5 GHz dipole-mode cavity BPM is still in the R&D phase, the re-entrant BPM has already passed first beam tests, including its read-out system. Furthermore, the LAPP group is developing radiation tolerant digital read-out systems, which are tested at the CLIC test facility (CTF).arXiv:0902.3017FERMILAB-CONF-08-664-ADoai:cds.cern.ch:11624302009-02-19
spellingShingle physics.acc-ph
Wendt, M.
Lefevre, T.
Simon, C.
Vilalte, S.
Status of the ILC Main Linac BPM R&D
title Status of the ILC Main Linac BPM R&D
title_full Status of the ILC Main Linac BPM R&D
title_fullStr Status of the ILC Main Linac BPM R&D
title_full_unstemmed Status of the ILC Main Linac BPM R&D
title_short Status of the ILC Main Linac BPM R&D
title_sort status of the ilc main linac bpm r&d
topic physics.acc-ph
url http://cds.cern.ch/record/1162430
work_keys_str_mv AT wendtm statusoftheilcmainlinacbpmrd
AT lefevret statusoftheilcmainlinacbpmrd
AT simonc statusoftheilcmainlinacbpmrd
AT vilaltes statusoftheilcmainlinacbpmrd