Cargando…
Status of the ILC Main Linac BPM R&D
An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently u...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2009
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1162430 |
_version_ | 1780915937467170816 |
---|---|
author | Wendt, M. Lefevre, T. Simon, C. Vilalte, S. |
author_facet | Wendt, M. Lefevre, T. Simon, C. Vilalte, S. |
author_sort | Wendt, M. |
collection | CERN |
description | An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently under investigation: A resonant dipole-mode cavity-style BPM pickup, developed at Fermilab, and a re-entrant resonant coaxial waveguide BPM, designed by CEA-Saclay. While the 1.5 GHz dipole-mode cavity BPM is still in the R&D phase, the re-entrant BPM has already passed first beam tests, including its read-out system. Furthermore, the LAPP group is developing radiation tolerant digital read-out systems, which are tested at the CLIC test facility (CTF). |
id | cern-1162430 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2009 |
record_format | invenio |
spelling | cern-11624302023-01-31T10:07:34Zhttp://cds.cern.ch/record/1162430engWendt, M.Lefevre, T.Simon, C.Vilalte, S.Status of the ILC Main Linac BPM R&Dphysics.acc-phAn introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently under investigation: A resonant dipole-mode cavity-style BPM pickup, developed at Fermilab, and a re-entrant resonant coaxial waveguide BPM, designed by CEA-Saclay. While the 1.5 GHz dipole-mode cavity BPM is still in the R&D phase, the re-entrant BPM has already passed first beam tests, including its read-out system. Furthermore, the LAPP group is developing radiation tolerant digital read-out systems, which are tested at the CLIC test facility (CTF).An introduction and the status of R&D activities for a high-resolution, 'cold' beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently under investigation: A resonant dipole-mode cavity-style BPM pickup, developed at Fermilab, and a re-entrant resonant coaxial waveguide BPM, designed by CEA-Saclay. While the 1.5 GHz dipole-mode cavity BPM is still in the R&D phase, the re-entrant BPM has already passed first beam tests, including its read-out system. Furthermore, the LAPP group is developing radiation tolerant digital read-out systems, which are tested at the CLIC test facility (CTF).arXiv:0902.3017FERMILAB-CONF-08-664-ADoai:cds.cern.ch:11624302009-02-19 |
spellingShingle | physics.acc-ph Wendt, M. Lefevre, T. Simon, C. Vilalte, S. Status of the ILC Main Linac BPM R&D |
title | Status of the ILC Main Linac BPM R&D |
title_full | Status of the ILC Main Linac BPM R&D |
title_fullStr | Status of the ILC Main Linac BPM R&D |
title_full_unstemmed | Status of the ILC Main Linac BPM R&D |
title_short | Status of the ILC Main Linac BPM R&D |
title_sort | status of the ilc main linac bpm r&d |
topic | physics.acc-ph |
url | http://cds.cern.ch/record/1162430 |
work_keys_str_mv | AT wendtm statusoftheilcmainlinacbpmrd AT lefevret statusoftheilcmainlinacbpmrd AT simonc statusoftheilcmainlinacbpmrd AT vilaltes statusoftheilcmainlinacbpmrd |