A Novel Time-Based Readout Scheme for a Combined PET-CT Detector Using APDs

This paper summarizes CERN R&D work done in the framework of the European Commission's FP6 BioCare Project. The objective was to develop a novel "time-based" signal processing technique to read out LSO-APD photodetectors for medical imaging. An important aspect was to employ the t...

Descripción completa

Detalles Bibliográficos
Autores principales: Powolny, F, Auffray, E, Hillemanns, H, Jarron, P, Lecoq, P, Meyer, T C, Moraes, D
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.2008.2004036
http://cds.cern.ch/record/1169273
_version_ 1780916109434683392
author Powolny, F
Auffray, E
Hillemanns, H
Jarron, P
Lecoq, P
Meyer, T C
Moraes, D
author_facet Powolny, F
Auffray, E
Hillemanns, H
Jarron, P
Lecoq, P
Meyer, T C
Moraes, D
author_sort Powolny, F
collection CERN
description This paper summarizes CERN R&D work done in the framework of the European Commission's FP6 BioCare Project. The objective was to develop a novel "time-based" signal processing technique to read out LSO-APD photodetectors for medical imaging. An important aspect was to employ the technique in a combined scenario for both computer tomography (CT) and positron emission tomography (PET) with effectively no tradeoffs in efficiency and resolution compared to traditional single mode machines. This made the use of low noise and yet very high-speed monolithic front-end electronics essential so as to assure the required timing characteristics together with a high signal-to-noise ratio. Using APDs for photon detection, two chips, traditionally employed for particle physics, could be identified to meet the above criteria. Although both were not optimized for their intended new medical application, excellent performance in conjunction with LSO-APD sensors could be derived. Whereas a measured energy resolution of 16% (FWHM) at the 511 keV photo peak competes favorably with that of 'classical' PMTs, the coincidence time resolution of 1.6 ns FWHM with dual APD readout is typically lower. This is attributed to the stochastic photon production mechanism in LSO and the photon conversion characteristic of the photo diode, as well as to the fluctuations in photon conversion, albeit the APD's superior quantum efficiency. Also in terms of CT counting speed, the chosen readout principle is limited by the intrinsic light decay in LSO (40 ns) for each impinging X-ray.
id cern-1169273
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-11692732019-09-30T06:29:59Zdoi:10.1109/TNS.2008.2004036http://cds.cern.ch/record/1169273engPowolny, FAuffray, EHillemanns, HJarron, PLecoq, PMeyer, T CMoraes, DA Novel Time-Based Readout Scheme for a Combined PET-CT Detector Using APDsHealth Physics and Radiation EffectsDetectors and Experimental TechniquesThis paper summarizes CERN R&D work done in the framework of the European Commission's FP6 BioCare Project. The objective was to develop a novel "time-based" signal processing technique to read out LSO-APD photodetectors for medical imaging. An important aspect was to employ the technique in a combined scenario for both computer tomography (CT) and positron emission tomography (PET) with effectively no tradeoffs in efficiency and resolution compared to traditional single mode machines. This made the use of low noise and yet very high-speed monolithic front-end electronics essential so as to assure the required timing characteristics together with a high signal-to-noise ratio. Using APDs for photon detection, two chips, traditionally employed for particle physics, could be identified to meet the above criteria. Although both were not optimized for their intended new medical application, excellent performance in conjunction with LSO-APD sensors could be derived. Whereas a measured energy resolution of 16% (FWHM) at the 511 keV photo peak competes favorably with that of 'classical' PMTs, the coincidence time resolution of 1.6 ns FWHM with dual APD readout is typically lower. This is attributed to the stochastic photon production mechanism in LSO and the photon conversion characteristic of the photo diode, as well as to the fluctuations in photon conversion, albeit the APD's superior quantum efficiency. Also in terms of CT counting speed, the chosen readout principle is limited by the intrinsic light decay in LSO (40 ns) for each impinging X-ray.oai:cds.cern.ch:11692732008
spellingShingle Health Physics and Radiation Effects
Detectors and Experimental Techniques
Powolny, F
Auffray, E
Hillemanns, H
Jarron, P
Lecoq, P
Meyer, T C
Moraes, D
A Novel Time-Based Readout Scheme for a Combined PET-CT Detector Using APDs
title A Novel Time-Based Readout Scheme for a Combined PET-CT Detector Using APDs
title_full A Novel Time-Based Readout Scheme for a Combined PET-CT Detector Using APDs
title_fullStr A Novel Time-Based Readout Scheme for a Combined PET-CT Detector Using APDs
title_full_unstemmed A Novel Time-Based Readout Scheme for a Combined PET-CT Detector Using APDs
title_short A Novel Time-Based Readout Scheme for a Combined PET-CT Detector Using APDs
title_sort novel time-based readout scheme for a combined pet-ct detector using apds
topic Health Physics and Radiation Effects
Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TNS.2008.2004036
http://cds.cern.ch/record/1169273
work_keys_str_mv AT powolnyf anoveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT auffraye anoveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT hillemannsh anoveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT jarronp anoveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT lecoqp anoveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT meyertc anoveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT moraesd anoveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT powolnyf noveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT auffraye noveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT hillemannsh noveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT jarronp noveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT lecoqp noveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT meyertc noveltimebasedreadoutschemeforacombinedpetctdetectorusingapds
AT moraesd noveltimebasedreadoutschemeforacombinedpetctdetectorusingapds