Electrical and calorimetric measurements and related software
During the incident of sector 3-4 on September 19th, the temperature of a number of magnets increased over the expected values prior to the circuit failure. A review of the data logged during powering tests on all circuits indicated potential resistive splices in sectors 1-2 and 6-7. Calorimetric an...
Autores principales: | Catalan-Lasheras, N, Charifoulline, Z, Koratzinos, M, Rijllart, A, Siemko, A, Strait, J, Tavian, L, Wolf, R |
---|---|
Lenguaje: | eng |
Publicado: |
2009
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1172380 |
Ejemplares similares
-
Calorimetric Power Measurements in X-band High Power RF
por: Wu, Xiaowei, et al.
Publicado: (2015) -
Strategy for consolidation to avoid incident and limit collateral damage: Summary of Session 4
por: Siemko, A, et al.
Publicado: (2009) -
High-Current Bus Splice Resistances and Implications for the Operating Energy of the LHC
por: Koratzinos, M, et al.
Publicado: (2010) -
Splice Resistance Measurements in the LHC Main Superconducting Magnet Circuits by the New Quench Protection System
por: Charifoulline, Z, et al.
Publicado: (2012) -
Methods to detect faulty splices in the superconducting magnet system of the LHC
por: Bailey, R, et al.
Publicado: (2009)