We describe the construction and tests of cryogenic X-ray windows of 47 mm diameter made of 15 ìm thick polypropylene foil glued on a UHV flange and supported with a strongback mesh machined by electro-erosion. These hermetic windows of the solar axion telescope of the CAST experiment at CERN withst...

Descripción completa

Detalles Bibliográficos
Autores principales: Niinikoski, T O, Bellanger, B, Davenport, M, Elias, N, Aune, S, Franz, J
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:http://cds.cern.ch/record/1173057
_version_ 1780916188523528192
author Niinikoski, T O
Bellanger, B
Davenport, M
Elias, N
Aune, S
Franz, J
author_facet Niinikoski, T O
Bellanger, B
Davenport, M
Elias, N
Aune, S
Franz, J
author_sort Niinikoski, T O
collection CERN
description We describe the construction and tests of cryogenic X-ray windows of 47 mm diameter made of 15 ìm thick polypropylene foil glued on a UHV flange and supported with a strongback mesh machined by electro-erosion. These hermetic windows of the solar axion telescope of the CAST experiment at CERN withstand the static and dynamic pressures of the buffer gas that are normally below 130 mbar, but may reach 1.2 bar when the magnet quenches. They were tested at 60 K up to 3.5 bar static pressure without permanent deformation.
id cern-1173057
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-11730572019-09-30T06:29:59Zhttp://cds.cern.ch/record/1173057engNiinikoski, T OBellanger, BDavenport, MElias, NAune, SFranz, JThin Cryogenic X-ray WindowsAccelerators and Storage RingsWe describe the construction and tests of cryogenic X-ray windows of 47 mm diameter made of 15 ìm thick polypropylene foil glued on a UHV flange and supported with a strongback mesh machined by electro-erosion. These hermetic windows of the solar axion telescope of the CAST experiment at CERN withstand the static and dynamic pressures of the buffer gas that are normally below 130 mbar, but may reach 1.2 bar when the magnet quenches. They were tested at 60 K up to 3.5 bar static pressure without permanent deformation.CERN-AT-2008-034oai:cds.cern.ch:11730572008-07-21
spellingShingle Accelerators and Storage Rings
Niinikoski, T O
Bellanger, B
Davenport, M
Elias, N
Aune, S
Franz, J
Thin Cryogenic X-ray Windows
title Thin Cryogenic X-ray Windows
title_full Thin Cryogenic X-ray Windows
title_fullStr Thin Cryogenic X-ray Windows
title_full_unstemmed Thin Cryogenic X-ray Windows
title_short Thin Cryogenic X-ray Windows
title_sort thin cryogenic x-ray windows
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1173057
work_keys_str_mv AT niinikoskito thincryogenicxraywindows
AT bellangerb thincryogenicxraywindows
AT davenportm thincryogenicxraywindows
AT eliasn thincryogenicxraywindows
AT aunes thincryogenicxraywindows
AT franzj thincryogenicxraywindows