Cargando…

Highly segmented thin microstrip detector with data-driven fast readout

In September 2008 the Slim5 collaboration submitted a low material budget silicon demonstrator to test with 12 GeV/c protons, at the PS-T9 test-beam at CERN. Inside the reference telescope, two different detectors were placed as device under test (DUT). The first was a 4k-Pixel Matrix of Deep N Well...

Descripción completa

Detalles Bibliográficos
Autor principal: Bomben, M.
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2010.02.181
http://cds.cern.ch/record/1175283
_version_ 1780916227537895424
author Bomben, M.
author_facet Bomben, M.
author_sort Bomben, M.
collection CERN
description In September 2008 the Slim5 collaboration submitted a low material budget silicon demonstrator to test with 12 GeV/c protons, at the PS-T9 test-beam at CERN. Inside the reference telescope, two different detectors were placed as device under test (DUT). The first was a 4k-Pixel Matrix of Deep N Well MAPS, developed in a 130 nm CMOS Technology, providing digital sparsified readout. The other one was a high resistivity double sided silicon detector, with short strips at 45-degree angle to the detector's edge, read out by the FSSR2 chip. The FSSR2 is a 128 channel data-driven fast readout chip developed by Fermilab and INFN. In this paper we describe the main features of latter sensor, the striplet. The primary goal of the test was to measure the efficiency and the resolution of the striplets. The data-driven approach of the FSSR2 readout chips has been fully exploited by the DAQ system.
id cern-1175283
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-11752832021-05-03T20:16:17Zdoi:10.1016/j.nima.2010.02.181http://cds.cern.ch/record/1175283engBomben, M.Highly segmented thin microstrip detector with data-driven fast readoutphysics.ins-detIn September 2008 the Slim5 collaboration submitted a low material budget silicon demonstrator to test with 12 GeV/c protons, at the PS-T9 test-beam at CERN. Inside the reference telescope, two different detectors were placed as device under test (DUT). The first was a 4k-Pixel Matrix of Deep N Well MAPS, developed in a 130 nm CMOS Technology, providing digital sparsified readout. The other one was a high resistivity double sided silicon detector, with short strips at 45-degree angle to the detector's edge, read out by the FSSR2 chip. The FSSR2 is a 128 channel data-driven fast readout chip developed by Fermilab and INFN. In this paper we describe the main features of latter sensor, the striplet. The primary goal of the test was to measure the efficiency and the resolution of the striplets. The data-driven approach of the FSSR2 readout chips has been fully exploited by the DAQ system.In September 2008 the Slim5 collaboration submitted a low material budget silicon demonstrator to test with 12 GeV/c protons, at the PS-T9 test-beam at CERN. Inside the reference telescope, two different detectors were placed as device under test (DUT). The first was a 4k-Pixel Matrix of Deep N Well MAPS, developed in a 130 nm CMOS Technology, providing digital sparsified readout. The other one was a high resistivity double sided silicon detector, with short strips at 45-degree angle to the detector's edge, read out by the FSSR2 chip. The FSSR2 is a 128 channel data-driven fast readout chip developed by Fermilab and INFN. In this paper we describe the main features of latter sensor, the striplet. The primary goal of the test was to measure the efficiency and the resolution of the striplets. The data-driven approach of the FSSR2 readout chips has been fully exploited by the DAQ system.arXiv:0905.0083oai:cds.cern.ch:11752832009-05-04
spellingShingle physics.ins-det
Bomben, M.
Highly segmented thin microstrip detector with data-driven fast readout
title Highly segmented thin microstrip detector with data-driven fast readout
title_full Highly segmented thin microstrip detector with data-driven fast readout
title_fullStr Highly segmented thin microstrip detector with data-driven fast readout
title_full_unstemmed Highly segmented thin microstrip detector with data-driven fast readout
title_short Highly segmented thin microstrip detector with data-driven fast readout
title_sort highly segmented thin microstrip detector with data-driven fast readout
topic physics.ins-det
url https://dx.doi.org/10.1016/j.nima.2010.02.181
http://cds.cern.ch/record/1175283
work_keys_str_mv AT bombenm highlysegmentedthinmicrostripdetectorwithdatadrivenfastreadout